Evaluation of the Influence on the Use of Additional Filtration in Pelvic Radiographic Examinations Using a Phantom Object

V. T. Claus, Flávio , A. P. Soares, A. P. Soares Flávio

Advances in Research · pp. 247–259 · Published 14 Aug 2023

10.9734/air/2023/v24i5975

Abstract

Aims: This study aimed to determine the effect of additional filtration on the image quality and dose reduction in pelvic radiographic examinations. Study Design:  Mention the design of the study here. Place and Duration of Study: The research was conducted at a municipal emergency service radiology department in Rio Grande do Sul, Brazil. Methodology: Using a simulator object to replicate clinical examination conditions. The radiographic equipment was fitted with aluminum, copper, and copper-aluminum composition filters to identify the optimal filtration for reducing radiation doses and maintaining image quality. Results: Results showed that filtration effectively reduced dose and average absorbed dose in internal organs, with the greatest reduction observed with the copper filter. However, excessive filtration resulted in a decrease in image quality, particularly with the copper filter. The Figure of Merit (FOM) demonstrated that keeping the electrical factors of the X-ray tube consistent (70 kVp and 32 mAs) and using an additional 2.5 mmAl filter could optimize pelvic radiographic examinations, based on the diagnostic IQ criteria established by the service. Conclusion: In conclusion, the FOM revealed that using additional filtration of 2.5 mmAl and maintaining the X-ray tube's electrical factors at 70 kVp and 32 mAs could reduce the KERMA in air by 49.8% in the patient, 41.5% in the testes, 35.5% in the bladder, 30.4% in the ovaries, 29.7% in the bone marrow, and 35.3% in the total effective dose of the examination, while maintaining equivalent image quality.

X-rays filtration digital radiography patient safety radiation dose

References (14)

  1. 1 International Commission on Radiological Protection [DOI]
  2. 2 Optimisation of image plate radiography with respect to tube voltage [DOI]
  3. 3 Updated effective doses in radiology [DOI]
  4. 4 Copper filtration in pediatric digital X-ray imaging: its impact on image quality and dose [DOI]
  5. 5 Image quality assessment with dose reduction using high kVp and additional filtration for abdominal digital radiography [DOI]
  6. 6 Radiological physics and technology
  7. 7 Impact of body part thickness on AP pelvis radiographic image quality and effective dose [DOI]
  8. 8 X-Ray Image Quality Assurance
  9. 9 An evaluation of the effect of tube potential on clinical image quality using direct digital detectors for pelvis and lumbar spine radiographs [DOI]
  10. 10 Dose optimization in pelvic radiography by air gap method on CR and DR systems – A phantom study [DOI]
  11. 11 Evaluation of patient radiation dose in routine radiographic examinations in Saudi Arabia [DOI]
  12. 12 Copper Filtration and kVp: Effect on Entrance Skin Exposure.
  13. 13 Effect of technical parameters on dose and image quality in a computed radiography system [DOI]
  14. 14 Influence of additional filters on radiation dose during chest radiography. [DOI]

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

103

Page views

0

PDF downloads

60

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.