Skip to content
Research Article Open access CC BY 4.0

Evaluating the Mechanical Properties of Fiberglass-reinforced Polymer Bar

George Oti Boateng, Charles K. Kankam, Edward C. Mansar, Russell O. Afrifa, Felix Kwarteng, Francis Ohene-Coffie, Selase A. K. Kpo

Journal of Engineering Research and Reports · pp. 150–160 · Published 20 Jun 2024

10.9734/jerr/2024/v26i71200

Abstract

This study examined the mechanical characteristics of glass fiber-reinforced polymer (GFRP) bars following its introduction in the Ghanaian construction industry. Tensile strength, tensile failure strain, and modulus of elasticity for different GFRP bar diameters were examined. The specimens were investigated according to the provisions in the British Standards. To conduct the tensile strength test on the GFRP, a gripping technique was required to prevent slippage or premature failure. The gripping mechanism comprised a circular steel pipe with an inner diameter of 22mm and 150mm long for gripping on both ends of the specimen where 150mm long of the GFRP bar was implanted into the steel pipe, leaving 300mm of free length. Thus, an appropriate embedment length and adequate pipe size were crucial components in this kind of gripping device. An epoxy mixture with expanding additives and high-strength non-shrink was used to fill the area between the steel pipe and the bar. The GFRP bar sizes used in this test were 10mm, 12mm, and 16mm and their tensile strength from the test results were 1193 N/mm², 1030 N/mm², and 866N/mm² respectively. The modulus of elasticity of the fiberglass also varied for the10mm, 12mm, and 16mm as 54434 MPa (N/mm²), 41711 MPa (N/mm²), and 30516 MPa (N/mm²) respectively. The ultimate strain for 10mm, 12mm, and 16mm was 2.20%, 2.48%, and 2.8% respectively. The measured values of ultimate strength, failure stresses, and axial tensile modulus correspond well with the values published in the relatively limited available literature. From the experimental data, the stress-strain relationship for all bar sizes was a single monotonic straight line. Thus, failure of the bars occurred suddenly without the warning that is usually associated with ductility beyond ultimate/maximum stress. Compared to conventional steel, fiber-reinforced polymers are highly robust and lightweight. Its mechanical properties, however, are linear elastic and lack a prominent yielding stage, which lowers the rates of elongation and failure strain. Furthermore, GFRP usually has a lower elastic modulus than steel, and unlike steel is non-homogeneous and an-isotropic.

Glass fiber tensile strength modulus of elasticity stress strain factor of safety

Cited by 5

Investigation on the Shear Performance of Concrete Beams Reinforced with Glass Fiber Reinforced Polymer (GFRP) Bars

Selase A. K. Kpo, Charles K. Kankam, Charles Osei Ababio · Asian Journal of Advanced Research and Reports · 2025

Structural Performance of Reused GFRP Bars in Reinforced Concrete Beams: A Sustainable Approach to Concrete Reinforcement

Charles K. Kankam, Selase A. K. Kpo, Russell O. Afrifa · Asian Journal of Advanced Research and Reports · 2025

Bond behaviour of BFRP Bars embedded in concrete under harsh conditions: A comprehensive review

Azzam Ahmed, Ali Tabatabaeian · Journal of Building Engineering · 2025

Flexural behavior of hybrid GFRP-steel reinforced concrete beam: Experimental and explainable artificial intelligence

Younes Nouri, Mohammad Ali Ghanbari, Pouyan Fakharian · Engineering Structures · 2025

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

5

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.