Skip to content
Research Article Open access CC BY 4.0

Comparison of Automated and Manual Methods for Antimicrobial Susceptibility Testing

Asifa Bhat, Dekyong Angmo, Shaista Nazir

Microbiology Research Journal International · pp. 43–48 · Published 11 Apr 2020

10.9734/mrji/2020/v30i230197

Abstract

Background: Carbapenems are considered the broadest-spectrum β-lactam agents and are often required for treatment of severe hospital-acquired infections caused by multidrug-resistant Gram-negative organisms. Minimum inhibitory concentrations (MICs) are important in diagnostic laboratories to confirm resistance of microorganisms to an antimicrobial agent and also to monitor the activity of new antimicrobial agents. Aims and Objectives: To compare the MIC obtained by Broth Microdilution method (BMD) with that of Vitek-2(automated method) for recovered isolates of Klebsiella pneumoniae. Materials and Methods: Prospective study conducted over a period of one year. It included all isolates of Klebsiella pneumoniae recovered from blood culture of the patients. The identification and antimicrobial susceptibility was done on Vitek-2.These Isolates were subjected to Microbroth dilution method for MIC determination. Results: Out of the 55 meropenem resistant  isolates by vitek-2, 20(36.3%) had MIC of ≥256 µg/ml followed by 18(32.7%) isolates with a MIC of 128 µg/ml, followed by 11(20%) isolates with MIC of 64 µg/ml and 6(10.9%) isolates with MIC of 32 µg/ml. Also among 15 meropenem sensitive isolates by Vitek-2, 13(86.7%) had MIC of ≤0.5 µg/ml, followed by two (13.3%) isolates with MIC of 2 µg/ml. Results obtained by vitek 2 were compared with those from BMD(the reference method), which showed a 13.3% minor error rate and no major or very major error rate. Conclusion: Overall, the Vitek 2 performance was comparable to that of BMD for testing a limited number of Klebsiella pneumoniae isolates.

Klebsiella pneumoniae minimum inhibitory concentration Vitek-2 MBD.

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.