Dental implant is considered to be the best treatment when dealing with the loss of teeth. It gives beautiful results and can last longer than most of other treatments. Since the Osseo-integration period is a critical period for implant stability, so the used material for dental implant is one of the most factors affecting the stability and Functionally Graded Material (FGM) is one of the opportunities to improve it. The aim of this research is to carry out modal analysis and vibration analysis analytically for functionally graded Dental Implant. In this study several models for dental implant was analyzed by ANSYS15.0 APDL. The functionally graded material was considered in three models. The same materials, Ti-HA, where used in all of them but with different ratio in each. The natural frequency and mode shapes were extracted for all models. The frequency responses of functionally graded Dental Implant after performing a static analysis for each modal have been studied. It was noticed using modal analysis that all of the extracted results for FGM are vary between the two basic materials and it is affected by the concentration of each. It is firmly believed that FGM is the future of dental implant due to the ability of designing a specific material property to be more stable. A comparison of the materials that utilized in FGM when the ration of each 100% was performed as well as an evaluation for the classical dental implant. It is firmly believed that FGM is the future of dental implant due to the ability of designing a specific material property to be more stable.

FGM dental implant vibrations modal analysis FEM

Cited by 1

A Study of the Effective Lifetime of Aluminum Buckets Used in Blood Bank Centrifuges

M. F. Tafti, R. Golestani, M. Salari · Engineering, Technology & Applied Science Research · 2017

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.