Comparative Study of Anterior Chamber Angle and Depth Recorded with Pentacam and AS-OCT SD “Spectralis”
Ophthalmology Research: An International Journal · pp. 1–12 · Published 21 Aug 2020
10.9734/or/2020/v13i330167Abstract
Aims: To compare the anterior chamber angle values recorded by Pentacam and AS-OCT SD “Spectralis” (Heidelberg Engineering) and present the correlation between the two devices. Sample and Study Design: A total of 50 patients were examined at the Private Ophthalmology Clinic O.M.M.A. Ophthalmological Institute. All participants volunteer to participate in this study where the data was kept anonymous. Patients aged 18-45 years without a pathological history were selected. All of them were emmetropes or with ametropia ranged ±0.75 D. There was no separation between hyperopic, myopic or emmetropic patients. Place and Duration of Study: University of West Attica Dept Biomedical Science Course Optics & Optometry in collaboration with Private Ophthalmology Clinic O.M.M.A. during the period between January 2019 to October 2019. Methodology: In this study, two basic structures of the eye are measured with the help of two devices of different principle of operation. Specifically, the study of the angle of the anterior chamber (ACA) as well as the depth of the chamber (ACD). The two devises are compared. Results: The ACA for both devices had mean difference of -2,004° for the R.E. while the mean difference for L.E. was 1,986°. Pentacam arithmetic mean ACA (R.E.) was 37,638 ± 2,98° and AS-OCT “Spectralis” 35,766 ± 2,90° with Correlation coefficient 0,7063 (P<0,0001). Pentacam arithmetic mean ACA (L.E.) was 37,638 ± 2,98° and AS-OCT “Spectralis” 35,652 ± 2,79° with Correlation coefficient 0,7569 (P<0,0001). The ACD for both devices had mean difference of -0,3028 for the R.E. while the mean difference for L.E. was -0,2860. Pentacam arithmetic mean ACD (R.E.) was 3,5866 ± 0,20 and AS-OCT “Spectralis” 3,2838 ± 0,20 with Correlation coefficient 0,4201 (P=0,0024). Pentacam arithmetic mean ACD (L.E.) was 3,558 ± 0,21 and AS-OCT “Spectralis” 3,2720 ± 0,20 with Correlation coefficient 0,4023 (P=0,0038). Conclusion: Values of ACA measured by Pentacam and AS-OCT “Spectralis” were similar within the sample population of normal eyes right and left (P<0,0001). ACD measured by Pentacam and AS-OCT “Spectralis” showed also similar results the sample population of normal eyes for the right eye (P=0,0024) and left (P=0,0038).
Cited by 0
No indexed citations yet.
Related research
- Comparison of Automated System Vitek-2 with Conventional Methods, for Identification and Antibiotic Sensitivity in Gram Negative Organisms — shares topic coverage
- Comparison between Indirect ELISA and TBIA for Detection of Some Viruses in Naturally Infected Faba Bean Plants — shares topic coverage
- Comparison for the Effectiveness of Column Purified Fractions of Allium cepa Bulbs and Allium sativum Cloves against Bulinus globosus (Intermediate Host of Urinary Schistosomiasis) in Sokoto, Nigeria — shares topic coverage
- Anthropometric Comparison of Nasal Indices between Hausa and Yoruba Ethnic Groups in Nigeria — shares topic coverage
- Comparison of Differences in TOEFL and TEM and Its Implications for Chinese Higher Education — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.