Skip to content
Research Article Open access CC BY 4.0

Development, Validation and Forced Degradation Study of Emtricitabine and Tenofovir Alafenamide in its Pharmaceutical Dosage Form Using RP-HPLC

Khushboo Patel, Ujashkumar Shah, Hirak Joshi, Jayvadan K. Patel, Tejas B. Patel

Journal of Pharmaceutical Research International · pp. 37–46 · Published 3 Sep 2021

10.9734/jpri/2021/v33i43A32462

Abstract

Aims: The present research was aimed to develop and validate a reverse phase high performance liquid chromatographic (RP-HPLC) method for the quantification of Emtricitabine (EMT) and Tenofovir Alafenamide (TEN) in combination. Methodology: Separation was achieved under optimized chromatographic condition on an Inertsil C18, 250 x 4.6 mm, 5μm column. Various composition of mobile phase was tried. Separation of EMT and TEN was started with Methanol: Buffer and Methanol finally using solvent system of Buffer (pH 3.5) and Methanol in ratio of (30:70) and flow rate adjust at 1.0 ml/min was used as solvent system, the detection was carried out at 262nm using Shimazdu UV-visible detector. The mobile phase run time for the developed analytical method was 10 minutes. Results: The standard curve was found linear in the concentration range of 20-60 μg/ ml (r2- 0.9994) and 2.5-7.5 μg/ ml (r2-0.9992) for EMT and TEN respectively. The %RSD was found to be 0.80-0.95% and 0.63-1.09 for EMT and TEN respectively. Percentage (%) recoveries for EMT and TEN to be in range of 100%-100.6% and 99.32%-100.83% respectively. The limit of detection and the limit of quantification were found to be 4.80 μg/ ml and 14.7 μg/ ml respectively for EMT and 0.11 μg/ ml and 0.33μg/ ml respectively for TEN. Results of forced degradation study showed EMT degradation in acid and base medium while TEN was showed degradation in oxidative stress. The proposed developed RP-HPLC method was validated statistically and the values were found to be within the acceptable limits. Conclusion: In conclusion, the developed RP-HPLC method was found to be simple, specific, and rugged for simultaneous estimation of EMT and TEN. Validation results of method was found within the acceptable limits. Hence it can be used for analysis of EMT and TEN.

Degradation RP-HPLC EMT TEN validation

Cited by 3

Showing 1 of 3 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

3

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.