Development of a Validated HPLC Method for the Estimation of Metformin HCl and Propranolol HCl
Venkata Srikanth Meka, Janaki Ram Battu, Senthil Rajan Dharmalingam, Adinarayana Gorajana, Venkata Ramana Murthy Kolapalli
Journal of Pharmaceutical Research International · pp. 1909–1922 · Published 3 Aug 2014
10.9734/BJPR/2014/10826Abstract
The present investigation targets to develop a simple, specific, sensitive and accurate reverse phase high performance liquid chromatographic (RP-HPLC) method in human plasma for the estimation of metformin HCl and propranolol HCl from bulk drug and also from the marketed products. Human plasma samples were subjected to correct procedure for protein precipitation by methanol and protein free plasma samples were directly injected into HPLC C18 column. Chromatographic determination was performed on a reversed phase C18 column (3.9 mm X 300 mm, particle size 5 µm) using a mixture of acetonitrile and 0.1M pH 4.5 potassium dihydrogenortho phosphate buffer (mL) (40:60) at a flow rate of 0.8 mL/min and maintained at a pressure of 140 to 150 Kg/cm2. The retention time for metformin HCl and propranolol HCl was found to be 9.084 min and 6.132 min respectively at 232 nm without any interference of endogenous compounds in the plasma. The method was linear in the range between 50-2000 ng/mL. The peak areas were reproducible as indicated by low coefficient of variation. It was found that the excipients in the tablet dosage form do not interfere in the quantification of active drug by proposed method.
Cited by 2
Pankaj Dwivedi, Priyata Kalra, Haiying Zhou · Pharmaceutics · 2025
Geetha Susmita A, Rajitha G, Ramya Yadav Y · Asian Journal of Pharmaceutical and Clinical Research · 2019
Related research
- Real Time Polymerase Chain Reaction versus Enzyme Linked Immunosorbent Assay in the Diagnosis of Cytomegalovirus Infection in Pregnant Women — shares topic coverage
- Home Recording And Video Selection: Their use In A Low-Resource Setting For Epilepsy Diagnosis — shares topic coverage
- Laboratory Performance Evaluation of Wantai HIV 1/2 Rapid Test Kit — shares topic coverage
- Performance of WRF’S Microphysics Options to Increase the Medium Range Rainfall Forecast Accuracy in Tamil Nadu Cauvery Delta Zone — shares topic coverage
- Remote Sensing and GIS Based Crop Acreage Estimation of the Rabi Season Growing Crop of the Middle Gujarat (India) — shares topic coverage
Article metrics
Real usage data collected on this platform.
8
Page views
0
PDF downloads
0
Outbound clicks
2
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.