Skip to content
Research Article Open access CC BY 4.0

Development and Validation of Estimation of Genotoxic Impurity (Benzimidamidecontent) in Leflunomide by Using RP-HPLC Technique

Mohan Bhatale, Neelakandan Kaliyaperumal, Gopalakrishnan Mannathusamy, Gurunathan Ramalingam

Journal of Pharmaceutical Research International · pp. 78–85 · Published 5 Oct 2021

10.9734/jpri/2021/v33i45B32782

Abstract

The measurement of Genotoxic contaminant, a simple, selective, linear, accurate, and specific reverse phase high-performance liquid chromatographic (RP-HPLC) process was proposed. A Benzimidamide impurity in the medication Leflunomide has been discovered. Separation and analysis were carried out on Zorbax SB phenyl (4.6 mm x 250 mm) with a particle size of 5.0 μm. with 0.1 % Triethylamine in purified water with a pH of 7.0 and a buffer of phosphoric acid (20% in water). The mobile phase is a 40:60 mixture of buffer and Acetonitrile with degassing. Isocratic program mode was used. The elution was carried out at a rate of 1.0 mL/min with UV detection at a wavelength of 289 nm. The temperature of the selected column oven is 25°C. The linearity and accuracy of Benzimidamide are covered in this approach, with a LOQ limit of 150 percent (i.e.0.03 to 0.45 ppm). The observed correlation coefficient is 0.99994, with a range of 100.01 to 104.8 for recovery. The measured percent RSD of six spiked test preparation is below 5.0 percent in procedure precision (i.e. repeatability) and intermediate precision (IP). When maintained at room temperature, the standard and sample remained stable for three days. System appropriateness characteristics such as tailing factor and percent RSD do not exhibit significant changes in robustness experiments. For the detection of Benzimidamide the present RP-HPLC method is act as selective, robust, linear and precise.

Benzimidamide RP-HPLC stability indicating genotoxic impurity

Cited by 2

Showing 1 of 2 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

2

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.