Comparison between 3 Dimentional Conformal Radiotherapy, Sequential Intensity Modulated Radiotherapy and Simultaneous Integrated Boost Intensity Modulated Radiotherapy as a Boost for Pelvic Lymph Nodes for Patients with Cancer Cervix
Mohamed Mahmoud, Sherweif Abdel Fatah, Amr Amin, Shaimaa Abdelgelil, Rasah A. Elawady, Abdullah Osama
Journal of Advances in Medicine and Medical Research · pp. 1–7 · Published 29 Oct 2018
10.9734/JAMMR/2018/44404Abstract
Aim: The study aims to Compare 3 Dimentional Conformal Radiotherapy (3DCRT), sequential Intensity Modulated Radiotherapy (sIMRT), Simultaneous Integrated Boost-Intensity Modulated Radiotherapy (SIB-IMRT) for positive pelvic lymph nodes for patients with cancer cervix treated with concurrent chemo-radiotherapy. Materials and Methods: C-T simulation was done for 10 patients with cervix cancer who had pelvic nodes, the clinical target volume (CTV) included the upper vagina, parametria, uterus, cervix, presacral area, and draining lymph nodes. One cm was added to form the Planning Target Volume (PTV). The organ at risk (OAR) included the bladder, rectum, pelvic bones marrow (PBM). Nodal CTV was expanded 7 mm to form nodal PTV. 3DCRT, sIMRT and SIB-IMRT planes were done. Doses of 3DCRT and sIMRT plans were 50 Gy to pelvic PTV with a nodal boost of 16 Gy in a total of 33 fractions while SIB plan treating the targets to the same doses in 25 fractions (i.e., 2 Gy per fraction to the pelvic PTV and 2.4 Gy per fraction to the boost PTV). Results: Comparable target volume coverage (V95%) was achieved with the 3 plans, maximum dose was significantly reduced using conformal plan for the boost plans with p= 0.01. Median dose for V45 of the rectum was the lowest with sIMRT (p= 0.015), the median dose for V50 of the bladder was the lowest in sIMRT plan (p= 0.007), the V10 of the bone marrow was low in the sIMRT plan (p= 0.015). Conclusion: The sIMRT boost for pelvic lymph nodes produce the same coverage as 3DCRT and SIB-IMRT and spares significantly the OAR.
Cited by 0
No indexed citations yet.
Related research
- Craniospinal Irradiation Using Three-Dimensional Conformal Radiotherapy with Two Different Planning Techniques: A Comparative Analysis in Supine and Prone Positions — shares topic coverage
- Assessment the Photo-neutron Contamination of IMRT and 3D-Conformal Techniques Using Thermo-luminescent Dosimeter (TLD) — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.