Skip to content
Research Article Open access CC BY 3.0

Clinical Study of Trans-catheter Closure of Patent Ductus Arteriosus with Occluder Devices among Children Aged 9 Months to 18 Years

I. O. Arodiwe, D. K. Adiele, J. M. Chinawa, V. Gouthami, K. S. Murthy, E. O. Obidike, J. C. Eze, F. Ujunwa

International Journal of TROPICAL DISEASE & Health · pp. 31–44 · Published 9 Oct 2013

10.9734/IJTDH/2014/6031

Abstract

Background and Objectives: This study was aimed at determining our experience with occluder devices over last 5 years. The objective of this study is to compare the complication rates and efficacy of different devices used for the closure of PDA. Methods: A cross-sectional retrospective study in which a review of the records of all children who had PDA surgery in a paediatric cardiac center, Innova Childrens’ Heart Hospital, Hyderabad, India over a five year period (June 2007 and July 2011) was undertaken. The hospital records showed that from June 2007 to July 2011, a total of 456 children aged 9 months to 18 years had trans-catheter closure over the study period, of these, 159 underwent trans-catheter device closure of PDA. A team of experienced paediatric cardiologist performed all the procedures. Results: Out of the 159 cases, 134 (84.2%) were successful while 25 (15.7%) were complicated. Five (5) {20.0%} cases had temporary residual leak, 3 (12.0%) had failure of the procedure that required surgical intervention, 9 (36.0%) had protrusion of the device into the aorta without significant Doppler pressure gradient. There exist a relation between success, complication and device used for the procedure.The type of occluder device used for the procedure significantly affect the outcome (χ2 = 16.37; p = 0.02) Chinese occlude devise had the highest success rate. Twenty five (25.0) {15.7%} patients had complications in all. The commonest complication (protrusion of the device into the aorta) was seen in 3 (1.8%) cases with Chinese duct occluder, 3(1.8%) with Sear Heart R and 3 (1.8%) cases with ADOs. Non died from the procedure. Conclusion: The commonest complication is (protrusion of the device into the aorta) with Chinese occludes devise showing the highest success rate. The learning curve and accumulating experience play an indispensable role in choosing the proper device and its size.

Patent ductus arteriosus Trans-catheter closure Duct occluder coil closure complications

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.