Skip to content
Research Article Open access

Retracted: Photoplethysmogram Technique to Characterize the Carotid-to-toe Pulse Duration during Different Human-postures

S. Abdalla, N. Al-Aama

Journal of Advances in Medicine and Medical Research · pp. 1–10 · Published 13 Jan 2017

10.9734/BJMMR/2017/30470

Abstract

Photoplethysmogram, including Pulse Transit Time (PTT), technique were used to detect blood volume changes in human carotid-to-toe. The main problem is how to evaluate the PTT values continuously from the subject with accurate readings. Monitoring PTT values of a person is useful in non-invasive, cuff-less estimation of blood pressure measurement. In this study, PTT values of 12 healthy subjects (8 males and 4 females) age 23.8 ± 1.5 years have been estimated using an auto-regressive with exogenous input (ARX) model. We presented autoregressive model for single variant and multi-variant model, using time series model, taken into account exogenous variables, a locally constant autoregressive model, and a radial basis function autoregressive model. We implemented the time domain system identification using an autoregressive with exogenous input (ARX) model. PTT values were estimated for all subjects in three different positions; sit, stand and supine. Results show that the PTT in sit and stand positions are statistically no different (84.5±19.6 ms versus 78±15.9 ms, p = 0.44). However, the PTT in the supine position is significantly higher than the two other positions (145.7±18.4 ms versus 84.5±19.6 ms and 145.7±18.4 ms versus 78±15.9 ms respectively, p < 0.01 for both situations). These results concur with values reported by other researchers (120 ms < PTT < 180 ms) on the effect of posture in estimating PTT.   Retraction Notice: This paper has been retracted from the journal after receipt of written complains. This journal is determined to promote integrity in research publication. This retraction is in spirit of the same. After formal procedures editor(s) and publisher have retracted this paper on 16th  August-2017. Related policy is available here: http://goo.gl/lI77Nn

Pulse photoplethysmogram ARX model transit time system identification time delay estimation

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.