Serum Amino Transaminases Activities and De Ritis Ratio amongst Apparently Healthy Secretors and Non-Secretors of ABH Substances Dwelling in Uyo Urban, Akwa Ibom State, Nigeria
Forwah Jacques Ndeh, Ebot Walter Ojong, Uwem Okon Akpan, Immaculate Ihuoma Ekeagba
Asian Journal of Research and Reports in Hepatology · pp. 1–20 · Published 5 Jan 2022
Abstract
Aims: The current study was designed to determine a local reference range of serum Alanine (ALT) and Aspartate (AST) activities and De Ritis ratio amongst apparently healthy secretors and non-secretors of ABH substances within Uyo, Akwa Ibom State, Nigeria, aged between 20 to 60 years for both genders. Study Design: The current study design was experimental and simple randomized sampling techniques was employed. Place: The current study was carried out in Uyo, Akwa Ibom, State, Nigeria. Duration of the Study: From 12th June to 6th December 2017. Methodology: About 2ml of saliva and 5ml of Blood samples were collected from 400 subjects by standard procedures and both serum ALT and AST activities were determined by a spectrophotometric techniques using commercial kit reagent produced by Sigma-Aldrich Cooperation Limited Liability Company, USA while ABH secretor status determined by Haemagglutination Inhibition Method using Anti-H -Lectin kits produced by BIOTEC Laboratories Limited, Suffolk, United Kingdom. Results: Statistically Chi-Squared (X2) test shows significant differences (P <0.05) between the means serum AST and ALT levels according to gender ((X2) = 4.99, P =0.025). No correlation found between serum ALT and AST activities with age and genders (r=0). De Ritis ratio = <1 according to gender, with no significant difference (P >0.05) between genders (t=2.44, P =0.1238,). Significant difference (P <0.05) between activities of ALT and AST in ABH secretor and non-secretors and sexes ((X2) =5.1, P =0.0239,). Chi Squared shows no significant differences in the mean prevalence rate ratio between gender (X2) = 3.2, df = 1, P = 0.07364, P >0.05). The prevalence rate ratio of ABH secretors and non-secretors was 4:1, according to ages and there was a significant difference (P <0.05) between male and female genders (t=2.44, P =0.1238,) Conclusion: AST and ALT references ranges in male ABH secretors subjects were higher than in female non-secretors subjects respectively.
Cited by 0
No indexed citations yet.
Related research
- Establishing the Normal Reference Range for Serum Ferritin, Percentage Transferrin Saturation and Soluble Transferrin Receptor Levels in Nigerian Population — shares topic coverage
- Association between Pyridoxal-5'-Phosphate Levels, Liver Homogenates and Serum Activities of Aminotransferases and De Ritis Ratio amongst Alcoholic Hepatitis Patients — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.