Skip to content
Research Article Open access CC BY 4.0

Parasinusal Atrial Tachycardia Mimicking Inappropriate Sinus Tachycardia: Successful ECG-Guided Ablation without Three-Dimensional Mapping: A Case Report

Jonathan Moyambi, S. ISMAIL ALFAKIHI, Fervent Ndukute, Haboub Meryem, Drighil Abdenasser

Asian Journal of Cardiology Research · pp. 47–52 · Published 31 Jan 2026

10.9734/ajcr/2026/v9i1351

Abstract

Background: Parasinusal atrial tachycardia (AT) is an uncommon form of focal supraventricular tachycardia that may closely mimic inappropriate sinus tachycardia (IST), creating diagnostic and therapeutic challenges. Differentiating these entities is crucial, as IST is primarily managed medically, whereas focal AT is amenable to curative ablation. Although three-dimensional (3D) electroanatomical mapping facilitates precise localization, it is not universally available, making surface electrocardiography (ECG) analysis essential. Case Summary: We report the case of a 54-year-old woman presenting with recurrent palpitations and dizziness. Initial ECG demonstrated a narrow-complex tachycardia with a ventricular rate of approximately 130 bpm. Detailed P-wave analysis revealed biphasic P waves in leads V1 and aVL, suggesting a right atrial origin. Electrophysiological study induced a parasinusal atrial tachycardia with earliest activation near the sinus node region, reproducing the patient’s symptoms. No evidence of accessory pathway or sinus node dysfunction was found. Despite beta-blocker therapy, symptoms persisted. Radiofrequency ablation was successfully performed using fluoroscopic guidance and ECG-based localization, without 3D mapping, resulting in complete arrhythmia suppression. Conclusion: This case highlights the diagnostic value of meticulous P-wave morphology analysis in distinguishing parasinusal AT from IST. Even in the absence of advanced mapping technologies, systematic ECG-guided localization can enable accurate diagnosis and effective curative ablation, particularly in resource-limited settings.

Parasinusal atrial tachycardia inappropriate sinus tachycardia P-wave analysis electrocardiography radiofrequency ablation supraventricular tachycardia arrhythmia management

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.