Epidemiology of Pacemaker Implantation among Patients in Tanta University Hospitals
Mahmoud Mohamed Ayed, Mohamed Bayoumi Nassar, Mohamed Naseem, Seham Fahmy Badr
Cardiology and Angiology: An International Journal · pp. 135–142 · Published 27 Jun 2022
10.9734/ca/2022/v11i430216Abstract
Background: This study describes cardiac pacing activity during 2021: demographic data of patients underwent permanent pacemaker implantation (PPM), risk factors, clinical presentations, indications, mode of pacing, and complications post PPM implantation. Cardiac pacemakers have become the common treatment of symptomatic bradycardia or high-grade atrioventricular block. Methods: The study was carried out at the department of cardiology Tanta University Hospitals. 102 patients were included in this study. This study was done over a period of six months from October 2020 until April 2021 and follow up for 6 months. All the data about the patients underwent permanent pacemaker implantation were collected by the coordinator in the participating cardiac center. Results: The most frequent risk factors of PPM implantation was hypertension (69%), followed by diabetes mellitus (29%), coronary artery disease (21%), chronic kidney disease (18%), hypothyroidism (6%), cardiomyopathy (3%), valvular heart disease (2%) and congenital heart disease (1%). The most common indication is complete heart block (69%), followed by second degree heart block "mobeitz type 2" (13%), slow atrial fibrillation (7%), symptomatic heart failure patients with LVEF ≤ 35% , QRS ≥ 150 ms (6%), trifascicular block (3%), sick sinus syndrome (2%). The most frequent mode of pacing used in our study was DDD mode (63%), followed by VVI mode (32%) with (78%) sinus rhythm and (22%) atrial fibrillation rhythm, then CRT-D (4%). Overall complication rate (9%) within 6 months. In our study the most common complication is infection (5%), followed by haematoma (1%), lead fracture (1%), pneumothorax (1%), and lead displacement (1%). Conclusion: Approximately three-quarters of the patients related to atrioventricular block underwent permanent pacemaker implantaion. Approximately more than half of pacemakers related to patients underwent permanent pacemaker implantation were dual chamber pacemakers. Infection is the most common complication in our study and this is important for strict infection control measures.
Cited by 0
No indexed citations yet.
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.