Assessment of Pupil Diameters in Pseudoexfoliation Syndrome under Scotopic, Mesopic, Photopic and Dynamic Conditions Using Infrared Pupillometer (Assessment of Pupil Diameters in Pseudoexfoliation Syndrome)
Ulviye YiÄŸit, Ismail Umut Onur, Ali Kutlay Tufan, Mehmet Fatih AÅŸula
Journal of Advances in Medicine and Medical Research · pp. 877–883 · Published 6 Apr 2015
10.9734/BJMMR/2015/16423Abstract
Aim: Our study aims to assess the mean pupil size under scotopic, mesopic, photopic and dynamic conditions in patients with PXS. Methodology: This study was performed in Ophthalmology Clinic at İstanbul Bakırköy Dr.Sadi Konuk Training and Research Hospital. Fourty-six patients with PXS and 46 age and sex matched controls were included in the prospective study. The subjects were allowed at least 3 minute to adapt to the lighting condition in the room. Pupil diameters were measured with infrared (IR) pupillometer integrated within CSO Sirius Corneal Topographer (Costruzione Strumenti Oftalmici S.r.l,Italy ) by the same examiner. The measurements were taken in scotopic, mesopic, photopic and dynamic conditions. Statistical analyses were evaluated. Results: Mean pupil diameter were significantly lower in the PXS group than control group for all measurements. Scotopic and mesopic pupil size were significantly lower in the PXS group than control group (p=0.0001). Also photopic and dynamic pupil size were significantly lower in the PXS group than control group (p=0.014, p=0.013). Conclusion: The results suggest that pupillary light response in patients with PXS significantly was affected not only in scotopic and mesopic conditions but also in photopic and dynamic conditions.
References (34)
- 1 Pupil Examination [DOI]
- 2 Preclinical Diagnosis of Pseudoexfoliation Syndrome [DOI]
- 3 Unilateral or Asymmetric Pseudoexfoliation Syndrome? [DOI]
- 4 Accommodation, pupil diameter and myopia [DOI]
- 5 Pupil Size in Refractive Surgery Candidates [DOI]
- 6 Repeatability of the Sirius Imaging System and Agreement With the Pentacam HR [DOI]
- 7 Comparison of the Colvard, Procyon, and Neuroptics Pupillometers for Measuring Pupil Diameter Under Low Ambient Illumination [DOI]
- 8 Call‐associated Acute Fatigue in Surgical Residents—Subjective Perception or Objective Fact? A Cross‐sectional Observational Study to Examine the Influence of Fatigue on Surgical Performance [DOI]
- 9 Scotopic measurement of normal pupils: Colvard versus Video Vision Analyzer infrared pupillometer [DOI]
- 10 Use of a digital infrared pupillometer to assess patient suitability for refractive surgery [DOI]
- 11 Comparison of a digital and a handheld infrared pupillometer for determining scotopic pupil diameter [DOI]
- 12 Agreement and repeatability of infrared pupillometry and the comparison method [DOI]
- 13 Pupil findings in a consecutive series of 150 patients with generalised autonomic neuropathy [DOI]
- 14 Visual acuity and the accuracy of the accommodative response [DOI]
- 15 Comparison of two pupillometers in determining pupil size for refractive surgery [DOI]
- 16 Digital pupillometry and centroid shift changes after cataract surgery [DOI]
- 17 Comparison of 3 Pupillometers for Determining Scotopic Pupil Diameter [DOI]
- 18 Colvard Pupillometer Measurement of Scotopic Pupil Diameter in Emmetropes and Myopes [DOI]
- 19 Monocular versus binocular pupillometry [DOI]
- 20 Pseudoexfoliationssyndrom [DOI]
- 21 Comparison of 2 multiple-measurement infrared pupillometers to determine scotopic pupil diameter [DOI]
- 22 Pseudoexfoliation syndrome: the puzzle continues.
- 23 Comparison of monocular and binocular infrared pupillometers under mesopic lighting conditions [DOI]
- 24 Scotopic measurement of normal pupil size with the Colvard pupillometer and the Nidek auto-refractor [DOI]
- 25 Comparison of a monocular pupillometer and the pupillometry function of a binocular free-viewing autorefractor [DOI]
- 26 Comparison of Rosenbaum Pupillometry Card Using Red and Blue Light to Colvard and Iowa Pupillometers [DOI]
- 27 Comparison of the Pupillometry During Videonystagmography in Asymmetric Pseudoexfoliation Patients [DOI]
- 28 Comparison of 2 monocular pupillometers and an autorefractor for measurement of the dark-adapted pupil diameter [DOI]
- 29 Intraocular Muscle Function in Pseudoexfoliation Syndrome [DOI]
- 30 Comparison of pupil diameter measurement with Lenstar LS 900 and OPD Scan II. Not interchangeable devices [DOI]
- 31 Repeatability of the Procyon P3000 Pupillometer [DOI]
- 32 Assessment of Pupil Diameters of Emmetropes and Myopes under Photopic, Mesopic and Scotopic Conditions, Using the Infrared Pupillometer Integrated Within Schwind Sirius Multifunctional Diagnostic Device [DOI]
- 33 Pupil Size in Refractive Surgery Candidates [DOI]
- 34 Call‐associated Acute Fatigue in Surgical Residents—Subjective Perception or Objective Fact? A Cross‐sectional Observational Study to Examine the Influence of Fatigue on Surgical Performance [DOI]
Cited by 18
Özlem Ural Fatihoğlu, Esra Vural, Ali Riza Cenk Çelebi · Journal of Glaucoma · 2023
Yücel Öztürk, Merve Beyza Yıldız, Rüveyde Bolaç · Ocular Immunology and Inflammation · 2021
Joanna Dereń-Szumełda, Mariola Dorecka, Mirosław Dereń · Life · 2025
Joanna Katarzyna Dereń-Szumełda, Mariola Dorecka, Łukasz Zandecki · Life · 2023
Kemal Tekin, Mehmet Ali Sekeroglu, Hasan Kiziltoprak · Journal of Glaucoma · 2018
Peter M. Maloca, Emanuel R. de Carvalho, Pascal W. Hasler · Acta Ophthalmologica · 2021
Kemal Tekin, Hasan Kiziltoprak, Mehmet Ali Sekeroglu · Clinical and Experimental Optometry · 2020
Gamze Yıldırım Biçer, Kürşad Ramazan Zor · International Ophthalmology · 2023
Showing 8 of 18 known citations — external sources report more than can currently be individually listed.
Related research
- The Association of Pseudoexfoliation Syndrome with Ventricular Repolarization Dynamics — shares topic coverage
- The Effect of Cataract Surgery on the Intraocular Pressure in Eyes with and without Pseudoexfoliation Syndrome — shares topic coverage
- Measurement of Choroidal Thickness in Patients of Pseudoexfoliation Syndrome Using Spectral Domain Optical Coherence Tomography — shares topic coverage
- Dynamics of Spermatogenesis — shares topic coverage
- Validating Response of AC Microgrid to Line-to-Line Short Circuit in Islanded Mode Using Dynamic Analysis — shares topic coverage
Article metrics
Real usage data collected on this platform.
61
Page views
0
PDF downloads
32
Outbound clicks
18
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.