Abstract

Hospital wastewater contains organic and inorganic pollutants as well as potentially hazardous biological and pharmaceutical constituents. This descriptive case study evaluated selected physicochemical indicators and operational practices at the wastewater treatment plant serving Kibuye Referral Hospital, Karongi District, Rwanda. Three occasions of influent and effluent sampling (April–May 2026) were supplemented by interviews with seven hospital and plant personnel. Ratios of reported mean influent and effluent concentrations were used to estimate apparent concentration reductions. Effluent means were 101.9 mg/L for five-day biochemical oxygen demand (BOD₅), 265 mg/L for chemical oxygen demand (COD), 66.0 mg/L for total suspended solids (TSS), 1,104 mg/L for total dissolved solids (TDS), and 40.7 mg/L for total nitrogen (TN); pH was 7.28. BOD₅, COD and TSS exceeded the respective 50, 250 and 50 mg/L screening values reproduced in Rwandan environmental guidance, whereas TDS was below its upper comparison value and pH was within the specified screening range. Apparent concentration reductions were 20.7% for BOD₅, 20.7% for COD, 62.6% for TSS and 41.6% for TDS. The TN estimates were indicative because the inlet series and analytical procedure were incompletely documented. Five of seven informants reported the absence of written inspection procedures, and six reported no wastewater-treatment training. The short sampling period and unmeasured hydraulic conditions preclude conclusions about longer-term treatment performance or permit compliance. Improved analytical traceability, routine monitoring and targeted process diagnostics are priority measures.

Hospital wastewater effluent screening physicochemical quality apparent removal treatment-plant operation Rwanda

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

6

Page views

0

PDF downloads

6

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.