Analysis of Isotopic Peaks in Hydrogen/Deuterium Exchange Mass Spectra for Precise Measurement of Isotope Average Centroid Mass of Peptides and Proteins Using R Programming Language
Arumugaperumal Arun, Sreekala Narayanan, Subhasis Sarangi, Amit Kumar Mandal
International Journal of Biochemistry Research & Review · pp. 1–8 · Published 9 Aug 2017
10.9734/IJBCRR/2017/35595Abstract
In hydrogen/deuterium exchange mass spectra, the shift in isotopically distributed peaks with deuterium incorporation into peptides results in an increase in the isotope average centroid mass. Due to limitations in the resolution of instruments and data processing by softwares, the observed peaks might have obscurity in its maxima values that can affect the centroid mass calculation. In the present study, using Gaussian function, the exact maxima of individual isotopic peaks of a distribution was calculated. Using those maxima and our customized program, the centroid mass was calculated. We propose that our method of calculating average centroid mass is mathematically more appropriate.
References (11)
- 1 CRC Handbook of Chemistry and Physics [DOI]
- 2 Probing Protein Ligand Interactions by Automated Hydrogen/Deuterium Exchange Mass Spectrometry [DOI]
- 3 HDX Workbench: Software for the Analysis of H/D Exchange MS Data [DOI]
- 4 Stepwise protein folding at near amino acid resolution by hydrogen exchange and mass spectrometry [DOI]
- 5 ExMS: Data Analysis for HX-MS Experiments [DOI]
- 6 Improved Protein Hydrogen/Deuterium Exchange Mass Spectrometry Platform with Fully Automated Data Processing [DOI]
- 7 Automated extraction of backbone deuteration levels from amide H/2H mass spectrometry experiments [DOI]
- 8 Hydra: software for tailored processing of H/D exchange data from MS or tandem MS analyses [DOI]
- 9 Conformational insight into multi-protein signaling assemblies by hydrogen–deuterium exchange mass spectrometry [DOI]
- 10 Automatic analysis of hydrogen/deuterium exchange mass spectra of peptides and proteins using calculations of isotopic distributions [DOI]
- 11 Comparative higher-order structure analysis of antibody biosimilars using combined bottom-up and top-down hydrogen-deuterium exchange mass spectrometry [DOI]
Cited by 0
No indexed citations yet.
Related research
- Instrumental Analysis of Foods: Inductively Coupled Plasma Mass Spectrometry for Determination of Metals in Cereals and Fast Ion Chromatography Analysis for Minerals in Sport Drinks — shares topic coverage
- Simple and Selective Determination of Free Chlorine in Aqueous Solutions by an Electrophilic Aromatic Substitution Reaction Followed by Liquid Chromatography Coupled with Mass Spectrometry — shares topic coverage
- Studies on the Isolation of 5, 3/, 4/-Trihydroxy, 7-Methoxy Isoflavone — shares topic coverage
- Assessment of Pesticide Residues in Fresh Vegetables from Three Major Markets in Lagos Using QuEChERS Method and GC-MS — shares topic coverage
- Studies on the Isolation of 5, 7-dihydroxy-3/, 4/-Dimethoxy Flavone from the Leaves of Cassia alata — shares topic coverage
Article metrics
Real usage data collected on this platform.
58
Page views
0
PDF downloads
37
Outbound clicks
0
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.