Sacred buildings like other types of buildings have to communicate to their users. Users must be comfortable and relate to the spaces provided in a positive way. When buildings are designed to respond passively to their climate, occupants feel comfortable and energy is conserved. The current paper surveys 11 churches within the Bantama locality of Kumasi. Against the background of the immense shortage of energy in Ghana, the study aimed at ascertaining whether these buildings conform to passive design strategies. In terms of orientation, the study revealed that only 45% of the churches were correctly oriented (longer sides facing the North-South orientation). Window to wall ratio also showed that out of the churches evaluated only one church fell within the range of 25 to 80% as recommended for buildings in the tropics. It was also recognized that these buildings did not have enough shading and as a result, there was a direct solar penetration into the indoor spaces causing visual and thermal discomfort. Adherence to sustainable design principles must be encouraged.  

Sacred architecture orientation windows passive

References (8)

  1. 1 Introduction to Architectural Science: The Basis of Sustainable Design
  2. 2 Solar radiation modelling using ANNs for different climates in China [DOI]
  3. 3 Simulation Based Analysis On The Effects Of Orientation On Energy Performance Of Residential Buildings In Ghana [DOI]
  4. 4 The Effects of Form and Orientation on Energy Performance of Residential Buildings in Ghana [DOI]
  5. 5 Parametric Studies on Window-To-Wall Ratio for Day lighting Optimisation in High-Rise Office Buildings in Kuala Lumpur, Malaysia
  6. 6 Contrasting the Principles behind the Orientation of Building Forms and Location of Spatial Components around the Globe [DOI]
  7. 7 Research on the Mahoney Tables Used in Shanghai Building Energy Efficiency Design [DOI]
  8. 8 A conceptual design approach to manage large earthquake forces [DOI]

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

27

Page views

0

PDF downloads

2

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.