Skip to content
Research Article Open access CC BY 4.0

In-vitro Measurement of Glucose Concentration in Human Blood Plasma Mixed Intralipid Phantom Samples by Using Modulated Ultrasound and Infrared Light

Anuj Srivastava, Md. Koushik Chowdhury, Shiru Sharma Sharma, Neeraj Sharma

Biotechnology Journal International · pp. 1–14 · Published 1 Apr 2016

10.9734/BBJ/2016/24861

Abstract

Non-invasive blood glucose measurement is one of most innovative domain in Biomedical Engineering. Multiple methodologies have-been introduced over last few decades to fulfil the clinical requirement for non-invasive glucose measurement in human beings, however, without a successful breakthrough. This research article uses modulated ultrasound with infrared light-based technique to study glucose-induced variations in human blood plasma mixed IntralipidTM phantom samples using infrared light of 940 nm and 40 kHz central frequency based ultrasonic transmitter unit. The test uses blood samples of 30 study subjects during oral glucose tolerance test and fasting, postprandial and random stages based blood glucose tests respectively. The result as obtained from oral glucose tolerance tests and fasting, postprandial and random stages blood glucose tests showed peak amplitude values in Fast Fourier Transform domain varies in corresponding to blood glucose levels in in-vitro samples. The Bland Altman plot, Error Grid and statistical analysis represent the potentiality and feasibility of our technique for non-invasive blood glucose measurement.

Non-invasive modulated ultrasound infrared light IntralipidTM phantom blood glucose

Cited by 6

Non-invasive sensing techniques for glucose detection: a review

Jamal Al-Nabulsi, Hamza Abu Owida, Jumana Ma’touq · Bulletin of Electrical Engineering and Informatics · 2022

Advancements and Challenges in Continuous Glucose Monitoring (CGM) Systems: A Review of Non-commercial and Commercial Technologies

Rasha Dheyaa Mahdi AL-Khafaji, Jaysuman Bin Pusppanathan, Ahmad Moolla · IFMBE Proceedings · 2025

A comprehensive review on electromagnetic wave based non-invasive glucose monitoring in microwave frequencies

Abhishek Kandwal, Yogeshwar Dutt Sharma, Rohit Jasrotia · Heliyon · 2024

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

6

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.