Skip to content
Research Article Open access CC BY 4.0

A Novel Synchronic Estimstion of Metronidazole, Ciprofloxacin and Doxycycline by RP-HPLC in Bulk and Pharmaceutical Formulation

Rama Rao Nadendla, Siva Prasad Morla, Abhinandana Patchala, Prachet Pinnamaneni

Journal of Pharmaceutical Research International · pp. 354–362 · Published 6 Dec 2021

10.9734/jpri/2021/v33i53A33670

Abstract

Aim: To design simple, rapid, new analytical method for estimation of Metronidazole, Ciprofloxacin Doxycycline by using RP-HPLC in bulk and pharmaceutical dosage form. Study Design: Estimation of Metronidazole, Ciprofloxacin Doxycycline by using RP-HPLC in bulk and pharmaceutical dosage form was planned and executed. Place and Duration of Study: Chalapathi Drug Testing Laboratory, Chalapathi Institute Of Pharmaceutical Sciences, Lam, Guntur-522034, Andhra Pradesh, India during the period of November 2019 to February 2020. Methodology: Metronidazole is an antibiotic and antiprotozoal medication. It is used either alone or with other antibiotics to treat pelvic inflammatory disease, endocarditis and bacterial vaginosis. Ciprofloxacin is an antibiotic used to treat a number of bacterial infections. Doxycycline is a tetracycline antibiotic that fights bacteria in the body. The study was carried out on SHIMADZU Prominance-i, LC-2030C system equipped with Shim-pack Gist (250 x 4.6 mm, 5μm) column and mobile phase was optimized by using mixture of methanol and 0.25mM potassium phosphate buffer in the ration of 60:40 v/v at a flow rate of 0.8 ml/min. The wavelength was set as 282nm at ambient temperature by injecting 20µl of solution and the run time was fixed for 10 min. Results: Linearity plot was constructed for concentration range of 5-15µg/ml for Metronidazole,5-15µg/ml for Ciprofloxacin and 1-8µg/ml for Doxycycline standard solutions. It shows best regression coefficient and y/s values. The accuracy of the proposed method was determined by performing recovery studies and was found between 98-102%. The repeatability testing for both sample and standard solutions the %RSD was found as <2.0% which is within the acceptable limits showing that the method is precise as well. The LOD and LOQ were found to be 0.33 and 0.99 µg/ml for Metronidazole, 0.33 and 0.99 µg/ml for Ciprofloxacin, 0.08 and 0.25 µg/ml for Doxycycline respectively. The proposed method was successfully applied for the pharmaceutical dosage form of Metronidazole, Ciprofloxacin Doxycycline and it was as economic, eco-friendly with less retention time around 10.0 min. Conclusion: The proposed method was validated in terms of linearity, range, Accuracy, precision, Specificity, Robustness. Method was successfully applied to the estimation of Metronidazole, Ciprofloxacin Doxycycline in combined marketed pharmaceutical dosage form.

Metronidazole ciprofloxacin doxycycline pharmaceutical formulation

Cited by 6

Investigated Uv/Visible Spectrophotometry Method for Determination of Doxycycline Monohydrate

Mukhlif Mohsin Slaihim, Menaa Abdul Salam Al-Abbasi, Ahmed Zaki Lafta · 2025

Investigated Uv/Visible Spectrophotometry Method for Determination of Doxycycline Monohydrate

Mukhlif Mohsin Slaihim, Menaa Abdul Salam Al-Abbasi, Ahmed Zaki Lafta · 2025

A Comprehensive Review of Analytical Techniques for Doxycycline and Its Metabolites

Hemn A. H. Barzani, Rebaz Anwar Omer, Nergz Bayiz Abdulrahman · Biomedical Chromatography · 2025

Article metrics

Real usage data collected on this platform.

1

Page views

0

PDF downloads

0

Outbound clicks

6

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.