Skip to content
Research Article Open access CC BY 4.0

Geophysical and Geotechnical Studies of a Proposed Structure at Akure, Southwestern Nigeria

Ilugbo Stephen Olubusola, Adebo A. Babatunde, Ajayi Oluwasayo Adegbola, Adewumi Olufemi Olaoluwa, Edunjobi Hazeez Owolabi

Journal of Engineering Research and Reports · pp. 1–12 · Published 10 Sep 2018

10.9734/jerr/2018/v2i29910

Abstract

Geophysical and geotechnical studies were carried out at a proposed location for the construction of a multi-storey structure in Akure, Southwestern, Nigeria. The aim was to ascertain the suitability of this location for both Founding and Engineering structures. The geophysical investigation involved the Vertical Electrical Sounding (VES) technique using the Schlumberger configuration, Dipole-Dipole Horizontal Profiling and a geotechnical investigation. A total of twenty-one (21) VES and five (5) Cone Penetration Test (CPT) locations were occupied within the study site. Dipole-Dipole Horizontal Profiling was occupied along traverses 1 and 2 within the investigated area. The electrode separation varies from 1 to 75 m. The investigation delineated three major layers which are topsoil, which is excavated before any foundation is laid. The second layer delineated was lateritic and the last was weathered layer. From the result obtained, depth to lateritic layer ranges from 1.1 to 9.0 m while resistivity defining the lateritic layer ranges from 150 Ωm to 792 Ωm. Some of the sounding curves generated over the VES stations and Dipole-Dipole Horizontal Profiling fairly correlated with those of the CPT profile. The high cone penetration resistance recorded at CPT point 4 and 5 is manifested as high geoelectric resistivity values recorded at VES 13. This shows that the soil has fairly low clay content. It also seen from the study that the geophysical studies has a greater depth penetration, and it also provide better layer characterization compared to geotechnical studies. The choice of foundation material, clay content and topography elevation should be taken into cognizance, since the load bearing capacity of the lateritic layer was appreciably high.

Vertical electrical sounding cone penetration test dipole-dipole foundation integrity

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.