Strength and Deformation Characteristics of Concrete Beams Reinforced with Glass Fibre Reinforced Polymer Bars
Selase A. K. Kpo, Charles K. Kankam, Francis Ohene-Coffie, George Oti Boateng, Ezekiel Sackitey Nanor, John K. Quarm Junior, Edward C. Mansal
Asian Journal of Advanced Research and Reports · pp. 151–169 · Published 3 Sep 2024
10.9734/ajarr/2024/v18i9741Abstract
This research presents findings from experiments conducted on the strength and deformation characteristics of concrete beams reinforced with Glass Fiber Reinforced Polymer (GFRP) bars and conventional steel bars as control. The mechanical properties of the GFRP bars and steel bars (10mm and 12mm nominal diameter) used were ascertained. A total of seven (7) reinforced concrete (RC) beams measuring 120mm x 200mm x 2000mm were cast, six (6) of which were GFRP reinforced and one (1) was steel reinforced, and were loaded incrementally until failure. Test variables of two concrete grades, C25 and C30, were adopted in conjunction with two tensile reinforcement ratios of 0.7% and 1.13% for the concrete beams. A uniform compression reinforcement ratio of 0.7% was implemented along with a transverse shear reinforcement ratio of 0.65% for all beams. The data gathered were analyzed using theoretical and experimental approach to provide an insight to deformation characteristics of the reinforced concrete beams cast. An estimation for the theoretical failure load from fracture of tension bars were based on a partial factor of safety (γm) of 1.52 for the tensile strength of GFRP. The study examined the deformational behavior including load-deflection response, crack propagation, flexural capacity and failure modes under a four-point monotonic loading test. The experimental results revealed that the GFRP reinforced concrete beams exhibited typical bilinear elastic behavior under static loading with a reduction in stiffness after cracking. The GFRP RC beams failed by sudden concrete crushing due to shear-bond failure, diagonal tension failure in the concrete, and flexural failure in contrast to the steel reinforced concrete beam which failed due to yielding of the steel tension bars. The investigation further highlighted that increasing the concrete compressive strength and the tensile reinforcement ratio of GFRP RC beams significantly improved their structural performance, reducing crack widths and increasing failure loads. GFRP RC beams recorded higher ultimate load capacities and deformations compared to steel-reinforced beams, despite their brittle failure modes. Further aligning with previous research, findings revealed that higher concrete strength leads to a greater number of cracks, but with reduced spacing and narrower widths.
Cited by 4
Selase A. K. Kpo, Charles K. Kankam, Charles Osei Ababio · Asian Journal of Advanced Research and Reports · 2025
Charles K. Kankam, Selase A. K. Kpo, Russell O. Afrifa · Asian Journal of Advanced Research and Reports · 2025
Selase A. K. Kpo, Charles K. Kankam, Charles Osei Ababio · 2025
Enock Tongyem, Stephen Asare, Selase A. K. Kpo · Discover Civil Engineering · 2026
Related research
- Research on the Bearing Capacity of the Cross Section of Reinforced Concrete Beams Strengthened with Increasing Section Method Considering the Effect of the Second Loading — shares topic coverage
- Investigation on the Shear Performance of Concrete Beams Reinforced with Glass Fiber Reinforced Polymer (GFRP) Bars — shares topic coverage
- Flexural Behavior of Reinforced Concrete Beams with Openings Created by PVC Pipes: An Experimental and Numerical Study — shares topic coverage
- The Investigations on the Physico-mechanical Properties of Jute Fiber Reinforced Unsaturated Polyester Resin (UPR) Composites — shares topic coverage
- Physical Properties of Expired Composite Resins After Air Fryer Thermal Treatment — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
4
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.