Optimization of Distribution Transformer Design for Harmonic Resilience using a Taguchi-FEM Approach
Samson Dauda Yusuf, Aminu Alhaji Abdulhamid, Barnabas John Kwaha
Advances in Research · pp. 1–20 · Published 1 Jan 2025
10.9734/air/2025/v26i11227Abstract
The Nigeria's low-voltage distribution transformers suffer from significant harmonic issues leading to catastrophic failures. Existing strategies to address harmonics have overlooked transformer inherent parameter design optimizations. This study presents the optimization of a 30 kVA transformer, focusing on enhancing efficiency and minimizing harmonic susceptibility for low-voltage distribution systems in Nigeria. Utilizing a combined Taguchi-FEM approach, result shows that key design parameters were optimized with core area (0.773 m²), material (Amorphous Steel), core design (Six-Stepped Core), and flux density (1.354T), resulting in a 27% reduction in energy losses. Finite Element Analysis (FEA) revealed that the optimized transformer exhibited a core saturation of 19.2%, significantly lower than the baseline's 42%, and demonstrated reduced energy density near the core-winding interface. Experimental validation through Open Circuit (OC) and Short Circuit (SC) tests confirmed a notable improvement in efficiency, with the optimized transformer achieving 97.15% efficiency at full load, compared to 95.5% for the baseline transformer. Core losses were reduced to 85W, and copper losses decreased to 800W. Also, the findings revealed a significant reduction in Total Harmonic Distortion (THD) from 16.78% in the baseline design to 4.12% in the optimized configuration. The findings align with international standards (IEC 60076-8). Optimizing core materials and stepped core design with advanced modeling can enhance reliability and reduce harmonic impacts. This study’s outcomes have potential promise on stable transformer operation, harmonic mitigation and reduced losses, enhanced reliability, and overall power systems stability; as well as the potential promise in terms of overall power systems cost savings and energy efficiency. Therefore, integrated optimization approaches, incorporating Taguchi-FEM and experimental techniques, can effectively enhance transformer performance, paving the way for broader applications in the field.
Cited by 0
No indexed citations yet.
Related research
- A Three Dimensional Finite Element Analysis for Contact Stress and Fatigue near the Fir-Tree Region in a Gas Turbine Blade — shares topic coverage
- A Study on Effect of Sizing Bolt Hole in Single-Lap Connection Using FEA — shares topic coverage
- Conceptual Design and Finite Element Analysis of a Five-Minute Mini D.C Powered Air Compressor for Inflating Automobile Tyres — shares topic coverage
- An Advanced Spherical Bearing Model with FEA Analysis — shares topic coverage
- Functionally Graded Coating Material of Cementless Knee Prosthesis — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.