Optimal Spike Detection Technique Based on Amplitude Threshold

U. Iruansi, S. T. Apeh

Current Journal of Applied Science and Technology · pp. 3539–3549 · Published 2 Jul 2014

10.9734/BJAST/2014/11459

Abstract

Spike detection as the first basic step is very important in analysing and classification of data, since the quality of resulting data depends crucially on a particular detection technique used. This paper presents the optimal spike detection technique based on amplitude threshold on a band pass filtered signal. Comparisons were made on four different filtered signals: voltage of the entire signal, power of the entire signal, voltage moving average and power moving average of the signal. MATLAB was used to generate six different realistic simulations with varying signal to noise ratio which resembles that of a real dataset. The six different simulations contain ten samples each. For each simulated signal, only one type of spike shape was used with same firing frequency following a Poisson distribution. The duration of the simulation was equal in all cases with the signal to noise ratio defined as the amplitude of the spikes normalized by the noise level. Also, the threshold for spike detection was calculated based on the estimation of the standard deviation of noise; the area under the receiver operating characteristic curve and statistical analysis of data were used to quantify their performance. The major finding is that the voltage technique superseded all other techniques mentioned above both in high and low signal to noise ratio. When voltage was compared with power, voltage moving average (vma) and power moving average (pma), it was observed that p (0.0022) < 0.05 and h = 1. This means that the test rejects the null hypothesis of equal medians. When power was compared with vma using Mann-Whitney U-Test, it was observed that p (0.0043) < 0.05 with h = 1, implying that the test rejects the null hypothesis of equal medians but when power was compared with pma, it was observed that p (0.1320) > 0.05 with h = 0, also implying that the test accepts the null hypothesis of equal medians. For comparison of vma and pma, it was observed that p (0.6991) > 0.05 with h = 0 which presents that the test accepts the null hypothesis of equal medians. However, is clear that voltage technique is the optimal spike detection technique based on amplitude threshold.

Spike detection voltage power voltage moving average power moving average and amplitude threshold

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.