The Role of IV Needleless Connectors and IV Complication Management and Prevention
Cynthia Chernecky, Denise Macklin
Advances in Research · pp. 195–206 · Published 3 Mar 2014
10.9734/AIR/2014/8475Abstract
The most common complications associated with vascular access devices are catheter related bloodstream infections (CR-BSI), which occur in acute care patients every minute, and occlusions. This review will address major issues associated with patient care and research associated with vascular access and intravenous (IV) needleless connectors including descriptions of different types of connectors, care and maintenance issues such as septum disinfection and flushing, education of students and practitioners, a new framework for research and relevant questions for healthcare practitioners to ask during patient assessment. Two overall strategies to prevent CR-BSI’s and occlusions; 1) prevent the active and passive migration of microorganisms into the fluid pathway and 2) prevent microorganism adhesion to the catheter surface will be discussed. The IV needleless connector, which is placed on the catheter hub is the gatekeeper to the intraluminal fluid pathway and its design directly impacts the success of strategies to prevent complications. Best practice requires that practitioners have specific knowledge of connector technology as well as patient factors for caring for vascular access devices. There is a large gap in the scientific literature and in policies and procedures related to evidenced based decision making associated with care and maintenance of needleless intravenous connectors. Understanding IV needleless IV connectors is necessary to meld research and practice together for best patient practices, so the occurrences of CR-BSI’s and occlusions can be mitigated and eliminated.
References (35)
- 1 Biofilms: Microbial Life on Surfaces [DOI]
- 2 A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection [DOI]
- 3 Nosocomial bloodstream infection in critically ill patients. Excess length of stay, extra costs, and attributable mortality [DOI]
- 4 Management of occlusion and thrombosis associated with long-term indwelling central venous catheters [DOI]
- 5 Evaluation of Outcome of Intravenous Catheter-related Infections in Critically Ill Patients [DOI]
- 6 Epidemiology, medical outcomes and costs of catheter-related bloodstream infections in intensive care units of four European countries: literature- and registry-based estimates [DOI]
- 7 Health Care–Associated Bloodstream Infections Associated with Negative‐ or Positive‐Pressure or Displacement Mechanical Valve Needleless Connectors [DOI]
- 8 Consequences of Intravascular Catheter Sepsis [DOI]
- 9 Cohort Study of the Pathogenesis and Molecular Epidemiology of Catheter-Related Bloodstream Infection in Neonates With Peripherally Inserted Central Venous Catheters [DOI]
- 10 Disinfection of Needleless Catheter Connectors and Access Ports With Alcohol May Not Prevent Microbial Entry: The Promise of a Novel Antiseptic-Barrier Cap [DOI]
- 11 Outbreak of Bloodstream Infection Temporally Associated with the Use of an Intravascular Needleless Valve [DOI]
- 12 Increased Catheter-Related Bloodstream Infection Rates After the Introduction of a New Mechanical Valve Intravenous Access Port [DOI]
- 13 Prevention of catheter-related bloodstream infection in critically ill patients using a disinfectable, needle-free connector: A randomized controlled trial [DOI]
- 14 Central venous catheter occlusion and thrombosis [DOI]
- 15 Prevention of Coagulase-Negative Staphylococcal Central Venous Catheter–Related Infection Using Urokinase Rinses: A Randomized Double-Blind Controlled Trial in Patients With Hematologic Malignancies [DOI]
- 16 Risk factors and preventive measures for catheter-related bloodstream infections [DOI]
- 17 Achieving Zero Catheter Related Blood Stream Infections: 15 Months Success in a Community Based Medical Center [DOI]
- 18 Comparative evaluation of five needleless intravenous connectors [DOI]
- 19 Incidence of Catheter-Related Bloodstream Infection Among Patients With a Needleless, Mechanical Valve–Based Intravenous Connector in an Australian Hematology-Oncology Unit [DOI]
- 20 Microbiologic evaluation of needleless and needle-access devices [DOI]
- 21 Central venous catheter occlusion: a prospective, controlled trial examining the impact of a positive‐pressure valve device [DOI]
- 22 Clinical evaluation of a positive pressure device to prevent central venous catheter occlusion: results of a pilot study.
- 23 Flushing ports of totally implantable venous access devices, and impact of the Huber point needle bevel orientation: experimental tests and numerical computation [DOI]
- 24 Caring for Patients With Cancer Through Nursing Knowledge of IV Connectors [DOI]
- 25 The Healthcare and Technology Synergy (HATS) Framework for Comparative Effectiveness Research as Part of Evidence-Based Practice in Vascular Access [DOI]
- 26 Reducing the risk of infection in vascular access patients: An in vitro evaluation of an antimicrobial silver nanotechnology luer activated device [DOI]
- 27 Comparison of Bacterial CFUs in Five Intravenous Connectors [DOI]
- 28 Nurses’ knowledge of intravenous connectors [DOI]
- 29 In vitro study assessing the antibacterial activity of three silver-impregnated/coated mechanical valve needleless connectors after blood exposure [DOI]
- 30 In Vitro Comparisons of Two Antimicrobial Intravenous Connectors [DOI]
- 31 Central venous catheter infection in adults in acute hospital settings [DOI]
- 32 In Vitro Connector Research [DOI]
- 33 The Impact of IV Connectors on Clinical Practice and Patient Outcomes [DOI]
- 34 Do needleless connectors increase bloodstream infection risk? [DOI]
- 35 Retraction notice to: Comparison of Central Line-Associated Bloodstream Infection Rates when Changing to a Zero Fluid Displacement Intravenous Needleless Connector in Acute Care Settings. Am J Infect Control. 2014;42:200–202. [DOI]
Cited by 9
Tuba Sengul, Betul Guven, Ayse Ferda Ocakci · American Journal of Infection Control · 2020
S. Matthew Gibson, Jonathan Primeaux · Journal of the Association for Vascular Access · 2020
Evonne Curran · Journal of Infection Prevention · 2016
Showing 3 of 9 known citations — external sources report more than can currently be individually listed.
Related research
- Overcrowding in an Emergency Department of a Referral Centre in Nigeria: A Study of National Orthopaedic Hospital, Igbobi, Lagos — shares topic coverage
- Assessment Patients’ Satisfaction Related on Quality of Care: A Cross-sectional Descriptive Study — shares topic coverage
- Practices of Nurses for the Care of Premature in Neonatal Intensive Care Unit: A Literature Review — shares topic coverage
- Nursing Care for Patients with Atrial Flutter Undergoing Catheter Ablation: Integrative Review — shares topic coverage
- Nursing Care for Patients Submitted to Coronary Transluminal Angioplasty: An Integrative Review — shares topic coverage
Article metrics
Real usage data collected on this platform.
62
Page views
0
PDF downloads
10
Outbound clicks
9
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.