Abstract

The radial flux density in the air-gap of rotating machines sets up a force of attraction between the stator and the rotor surfaces. In a symmetrical machine, the radial stresses distributions are balanced resulting in zero net force on the rotor. However, if the rotor of a rotating machine is supported eccentrically with respect to the stator or if rotor short circuits occur, a one-sided magnetic force will be developed which generally tends to increase the eccentricity and increases considerably the critical speed of the machine. The resultant force created by the unbalanced forces of attraction is called unbalanced magnetic pull (ump). Under certain conditions these forces may cause the individual parts of the machine to vibrate and thus develop a noise. The vibrating parts are more stressed and are frequent sources of troubles, they also cause a rapid ageing of the machine. Furthermore, the  machine  vibrations  are  transferred  to  the bases and may, with  large  machines,  cause a  vibration  of  the  entire surroundings of the machine. In the following paper a brief outline of the mathematical analysis associated with a technique for monitoring defects in rotating machine whilst the machine is running in normal service is described. This technique is based upon the use of sensors in the air-gap, so arranged that the symmetrical air-gap is eliminated and only the lack of symmetry due predominantly to the missing flux associated with electrical and mechanical failures (eccentricity, increased vibrations, bending of the rotor shaft etc.), are displayed. A small four-pole machine with a modified field winding and bearings is used to examine experimentally both electrical and mechanical anomalies of various magnitude and position.  

Synchronous machines turbogenerators drive systems anomalies monitoring harmonics diagnosis

References (12)

  1. 1 Parameter Estimation, Condition Monitoring, and Diagnosis of Electrical Machines [DOI]
  2. 2 Condition monitoring and fault diagnosis of electrical machines-a review [DOI]
  3. 3 Vibration and current monitoring for detecting airgap eccentricity in large induction motors [DOI]
  4. 4 Comparison of the Unbalanced Magnetic Pull Mitigation by the Parallel Paths in the Stator and Rotor Windings [DOI]
  5. 5 Finite-Element Analysis of Unbalanced Magnetic Pull in a Large Hydro-Generator Under Practical Operations [DOI]
  6. 6 Saturation Effects on Unbalanced Magnetic Pull in a Hydroelectric Generator With an Eccentric Rotor [DOI]
  7. 7 Detection of Rotor Faults in Synchronous Generators [DOI]
  8. 8 Rotor winding short detection [DOI]
  9. 9 Methods for diagnosing static eccentricity in a synchronous 2 pole generator [DOI]
  10. 10 Identification of principal factors causing unbalanced magnetic pull in cage induction motors [DOI]
  11. 11 Induction motor bearing fault identification using vibration measurement [DOI]
  12. 12 Motor fault detection using vibration patterns [DOI]

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

49

Page views

0

PDF downloads

11

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.