Unintentional Common Carotid Artery Cannulation During Attempted Internal Jugular Vein Catheterization: A Case Report
International Journal of Medical and Pharmaceutical Case Reports · pp. 43–46 · Published 5 Jul 2025
10.9734/ijmpcr/2025/v18i3434Abstract
Central venous catheter placement is a common procedure, performed on a daily basis. It is relatively a safe procedure, with low complication rate. However serious complications can occur, especially in cases of inadvertent artery cannulation. The consequences can be devastating, if the situation is not immediately recognised and managed. The preferred sites for cental venous cannulation are the right sublavian or the right internal jugular vein. Arterial puncture is a well-recognized complication, while unintended subclavian or carotid artery cannulation during attemped central venous catheterization are infrequent, but documented complications. Endovascular or surgical treatment can be employed to repair inadvertent arterial cannulations. This paper presented a case of a female patient after abdominal surgery, who had an attempt of placement of central venous catheter in the intensive care unit, because the need for optimal delivery of drugs, fluid and parenteral nutrition. During the attempt of the right internal jugular vein cannulation, the carotid artery was cannulated. The situation was immediately recognised and managed by a vascular surgeon. The patient recovered completely without any neurological decifit.
Cited by 0
No indexed citations yet.
Related research
- Epidemiological Analysis of Infective Endocarditis at the Gold Coast Area Health Service, Australia — shares topic coverage
- Pattern of Hypertension in Fayoum Governorate — shares topic coverage
- An Update on Laparoscopic Inguinal Hernia Repairs: Narrative Review — shares topic coverage
- An Updated Review on Percutaneous Cholecystostomy in Acute Calculus Cholecystitis — shares topic coverage
- Recurrent Glaucoma Drainage Device Erosion Associated with Occult Infection with Biofilm-producing Organisms — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.