Skip to content
Research Article Open access CC BY 3.0

Transmittance Properties of Contact Lens Multipurpose Solutions and Their Effects on a Hydrogel Lens

Kelechi C. Ogbuehi, Faisal M. J. Khan, Saud A. Alanazi, Turki M. AlMubrad, Uchechukwu L. Osuagwu

Annual Research & Review in Biology · pp. 2484–2500 · Published 18 Apr 2014

10.9734/ARRB/2014/7934

Abstract

Purpose: The aim was to assess the compatibility of different multipurpose solutions (MPSs) with one type of silicone hydrogel (SiH) contact lens by, assessing the changes in both ultraviolet (UV) and visible light transmissibility of the hydrogel lens caused by the MPSs. Methods: The light transmittance from 200-700 nm were measured for the lotrafilcon B blister pack solution (BPS), six MPSs namely, ReNuMultiPlus Multi-Purpose Solution (Bausch and Lomb Inc., Rochester NY, USA.); Complete RevitaLens Multi-Purpose (Abbott Medical Optics Inc., Quarryvale Co. Dublin, Ireland); All In One Light (Sauflon Pharmaceuticals Ltd., Twickenham, England); SOLO-care AQUA™ (Ciba Vision Corporation Duluth, Georgia, USA.); Biomedics All-in-one solution (CooperVision, Hamble, UK); and HippiaMultiPlus All-in-one solution (Interojo Inc., Kyeonggi-do, Korea), and a lotrafilcon B SiH lens (before and after storage), using a spectrophotometer. Results: The UV transmitted through the BPS and the MPS were similar (p >.05, for all), except for the HippiaMultiPlus which was lower (p < 0.001) by 19.8%. Mean transparency values were statistically (p<.001) significantly different between the BPS and the MPSs. All MP solution/SiH lens combinations resulted in relatively high UV transmittance values especially in the UVC spectrum, and significantly increased (p <.001) the visible light transmittance values of the SiH lens. Greater changes in transparency were observed in the ReNu/SiH lens (28.5%) and the Complete RevitaLens/SiH lens (24.9%) combinations. Conclusion: The six MPSs showed significant variations in the transmitted UV and visible light. Similar to the BPS, all MPSs were equally transparent, but showed very poor UVA & UVB attenuation, except for the Hippia MultiPlus. The MPS/SiH lens combinations did not significantly affect the lens transparency but it significant increased the lens transmittance of UV radiation, after storage. Further in-vivo studies are needed to validate if this effect is constant.

Contact lens Multipurpose Solution (MPS) Blister Pack Solution (BPS) ultraviolet light transmission electromagnetic spectrum.

References (22)

  1. 1 INTERNATIONAL COMMISSION ON NON-IONIZING RADIATION PROTECTION [DOI]
  2. 2 Biocide Uptake in Contact Lenses and Loss of Fungicidal Activity During Storage of Contact Lenses [DOI]
  3. 3 Prevalence, use and sale of contact lenses in Saudi Arabia: Survey on university women and non-ophthalmic stores [DOI]
  4. 4 Cytotoxicity and antimicrobial activity of six multipurpose soft contact lens disinfecting solutions 1 [DOI]
  5. 5 Physical Properties of Soft Contact Lens Solutions [DOI]
  6. 6 Development of a new contact lens multipurpose solution: Comparative analysis of microbiological, biological and clinical performance [DOI]
  7. 7 UV-Induced Signaling Pathways Associated with Corneal Epithelial Cell Apoptosis [DOI]
  8. 8 The significance of ultraviolet radiation for eye diseases A review with comments on the efficacy of UV-blocking contact lenses [DOI]
  9. 9 Ultraviolet (UV) transmittance characteristics of daily disposable and silicone hydrogel contact lenses [DOI]
  10. 10 Changes in UV‐Visible Transmittance of Silicone‐Hydrogel Contact Lenses Induced by Wear [DOI]
  11. 11 Surface Interactions on Hydrogel Extended Wear Contact Lenses [DOI]
  12. 12 Soft contact lens care regimens in the UK [DOI]
  13. 13 Study of ultraviolet radiation and genotoxic effects of natural sunlight in relation to skin cancer in Saudi Arabia.
  14. 14 Amoebicidal Activity of Multipurpose Contact Lens Solutions [DOI]
  15. 15 Comparative efficacies of contact lens disinfecting solutions against Pseudomonas aeruginosa [DOI]
  16. 16 In vivo Cataract after Repeated Exposure to Ultraviolet Radiation [DOI]
  17. 17 Ultraviolet transmittance of the vistakon disposable contact lenses [DOI]
  18. 18 Lymphocytic Reaction to Ultraviolet Radiation on Rabbit Conjunctiva [DOI]
  19. 19 Antifungal efficacy of soft contact lens disinfecting solutions against Fusarium solani and Candida albicans [DOI]
  20. 20 Ocular Effects of Near Ultraviolet Radiation [DOI]
  21. 21 Current contact lens care systems [DOI]
  22. 22 The effects of ophthalmic solutions on the transmission of light through hydrogel lenses.

Cited by 4

Interactions between contact lenses and lens care solutions: Influence in optical properties.

Micael Alves, E. Castanheira, M. Lira · Contact lens & anterior eye : the journal of the British Contact Lens Association · 2021

Showing 3 of 4 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

42

Page views

0

PDF downloads

22

Outbound clicks

4

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.