Performance Evaluation and Optimization of a Two Horse Power Concentric Tube Heat Exchanger
Ibiam Prince Amauche, Udonne Joseph, Jeremiah Saviour. H, Ezeamama Lilian
Journal of Engineering Research and Reports · pp. 28–38 · Published 14 May 2022
10.9734/jerr/2022/v22i717547Abstract
The aim of this research work was to improve the performance of a two horse power (2hp) shell and tube heat exchanger. The available area obtained from calculation is 3.77×10-³m2 and 383.75W/M²K. Overall heart transfer coefficient was obtained. The heat exchanger was satisfactory and consists of one pass copper tube of internal diameter 10mm and length 120mm. The shell length and internal diameter of the shell are 95mm and 60mm respectively. The concentric tube heat exchanger has a total length of 245mm and 136mm width. The hot fluid passes through the copper tube while the cold fluid move on the annulus made of mild steel. The results of the experiment shows that the heat was transferred from the hot fluid gradually move counter currently to the cold fluid in the same direction of flow. Mild steel was used for the construction of the shell while copper was used for the tube. The efficiency is 51.89% was obtained. This confirmed that the optimized equipment is more efficient than initial machine performance efficiency of 40.76%. Significantly, this equipment is of great need when vaporized liquid must be recovered back as liquid at specified conditions and also control the flow of thermal energy between two terminals.
Cited by 0
No indexed citations yet.
Related research
- Performance Evaluation of DBSKKV Developed Fruit harvesters for Matured Nutmeg Harvesting — shares topic coverage
- An Application of Fuzzy Canonical Correlation and Fuzzy DEA for Ranking Bank Branches — shares topic coverage
- Performance Evaluation of a Low-cost Cold Storage System on Fruits and Vegetables in Rural Areas — shares topic coverage
- Comparative Analysis and Performance of Solar Dryers with Backup Incinerators for Nsukka Sub-tropical and Makurdi Humid Locations Using Selected Farm Produce — shares topic coverage
- Application of N2 Method for Performance Evaluation of Reinforced Concrete Framed Asymmetric Edifices — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.