The Effect of Delayed Scanning of Photostimulable Phosphor Plates on Inter-proximal Caries Detection
Ehsan Tavakoli, Jale Shafiei Sabet, Mahjube Entezarghaem, Fatemeh Nadaf, Elahe Shafiei Rad
Journal of Pharmaceutical Research International · pp. 1–7 · Published 24 Jun 2019
10.9734/jpri/2019/v28i230196Abstract
Objectives: The aim of this study was to determine the effect of different scan delays and different kVps on the diagnostic accuracy of inter-proximal caries detection in photostimulable phosphor plates (PSPs). Materials and Methods: 45 non-cavitated extracted human posterior teeth were radiographed using the DIGORA® PSPs (Soredex Corporation, Helsinki, Finland). The plates were exposed at 60 kVp and 70 kVp were scanned immediately, 10 min, 30 min, 1h, 6 h, 24 h and 48 h after exposure. In between the exposure and the scan period, the plates were stored in light-tight boxes. The true presence of caries was determined by sectioning the teeth mesiodistally. The accuracy was expressed as the area under ROC curve (AZ). The AZs were compared using SPSS version17 software and repeated measurement test. Kappa was used to measure inter and intra observer agreement. Results: There was no significant difference between caries detection AZs of the images that were scanned immediately and within 30 min after exposure at 60 kVp and 70 kVp (P >0.05). The immediately scanned AZ at 60 kVp was significantly higher than the AZs with 6 h, 24 h and 48 h scan delays (P <0.05). the immediately scanned AZ at 70Kvp was significantly higher than the AZs of 1 h, 6 h, 24 h and 48 h (P <0.05). Conclusions: PSP scanning should not be delayed higher than 30 min in order to have an accurate proximal caries detection. Longer delays may cause loss of quality of images.
References (7)
- 1 The Measurement of Observer Agreement for Categorical Data [DOI]
- 2 Oral Radiology: Principles and Interpretation
- 3 Sturdevant's Art and Science of Operative Dentistry [DOI]
- 4 Analysis of digital images acquired using different phosphor storage plates (PSPs) subjected to varying reading times and storage conditions [DOI]
- 5 Degradation of storage phosphor images due to scanning delay [DOI]
- 6 Evaluation of the effects of processing delays and protective plastic cases on image quality of a photostimulable phosphor plate system [DOI]
- 7 Effect of visible light on photo-stimulated-phosphor imaging plates [DOI]
Cited by 0
No indexed citations yet.
Related research
- Prevalence and Risk Factors of Dental Caries among Preparatory School Children, Menoufia Governorate, Egypt — shares topic coverage
- Fast Food Consumption and Dental Caries among Teenagers — shares topic coverage
- Detecting Dental Caries through Captured Images Using the Machine Learning Technology Teachable Machine — shares topic coverage
- Smokeless Tobacco – Ammunition against Dental Caries? A Microbial Study — shares topic coverage
- Bacterial Profile Associated with Dental Caries in Jos, Nigeria — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.