Simulation-based Assessment of the Thermal Performance of High-rise Office Buildings in Ghana
Barbara Simons, Christian Koranteng, Joshua Ayarkwa
Current Journal of Applied Science and Technology · pp. 165–179 · Published 27 Mar 2015
10.9734/BJAST/2015/16700Abstract
The lack of empirical data and practical advice on thermal performance and efficient use of energy in our buildings are gradually becoming a burden to the country. Amidst the recent development in the usage of curtain walls for office buildings, high utilization of energy and poor thermal comfort issues have become paramount. Given the warm-humid climatic characteristics of Ghana, energy requirements for cooling of office buildings represent a growing burden for the environment and the economy. The current paper explores the implications of alternative design options for the thermal performance of four high-rise office buildings in Accra, Ghana. Multiple design alternatives were considered involving various glazing types, shading and shading schedules, thermal insulation options, lighting, various ventilation options and thermal mass. A numeric thermal simulation application was used to model the performance of these alternatives parametrically. Simulation results were expressed in terms of annual cooling loads (active building operation scenario) and mean overheating (passive building operation scenario). Careful combination of improvement measures (such as efficient glazing, thermal mass, façade insulation, night ventilation, efficient electrical lighting, form and orientation) has a significant potential to reduce buildings' cooling loads (31% – 49%) in the climatic context of Accra. Over-heating tendencies were also reduced from 8.6K to 3.9K depending on the air-change-rate per hour (ACH).
References (23)
- 1 Thermal comfort and building energy consumption implications – A review [DOI]
- 2 The impact of shading design and control on building cooling and lighting demand [DOI]
- 3 Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: a literature review [DOI]
- 4 Introduction to Architectural Science: The Basis of Sustainable Design
- 5 Towards a psycho-physiological model of thermal perception [DOI]
- 6 Controlled natural ventilation for energy efficient buildings [DOI]
- 7 Effect of envelope colour and thermal mass on indoor temperatures in hot humid climate [DOI]
- 8 An investigation of the potential for natural ventilation and building orientation to achieve thermal comfort in warm and humid climates [DOI]
- 9 Experimental evaluation of night ventilation phenomena [DOI]
- 10 Effect of fixed horizontal louver shading devices on thermal perfomance of building by TRNSYS simulation [DOI]
- 11 The Effects of Orientation, Ventilation, and Varied WWR on the Thermal Performance of Residential Rooms in the Tropics [DOI]
- 12 Design of passive cooling by night ventilation: evaluation of a parametric model and building simulation with measurements [DOI]
- 13 Thermal and lighting behavior of office buildings in Santiago of Chile [DOI]
- 14 Nonlinear coupling between thermal mass and natural ventilation in buildings [DOI]
- 15 Effects of Thermal Mass, Window Size, and Night‐Time Ventilation on Peak Indoor Air Temperature in the Warm‐Humid Climate of Ghana [DOI]
- 16 THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING
- 17 A study on the proposes of energy analysis indicator by the window elements of office buildings in Korea [DOI]
- 18 Limits and potentials of office building climatisation with ambient air [DOI]
- 19 Modelling to predict future energy performance of solar thermal cooling systems for building applications in the North East of England [DOI]
- 20 Unveiling Energy Saving Techniques for Cooling in Residential Buildings in Ghana [DOI]
- 21 Thermal simulation as design tool for residential buildings in Southeast Asia
- 22 Natural Night Ventilation in Office Buildings: Performance Evaluation Based on Simulation, Uncertainty and Sensitivity Analysis
- 23 Envelope design for thermal comfort and reduced energy consumption in residential buildings
Cited by 2
M.N. Addy, E. Adinyira, J. Ayarkwa · Energy Procedia · 2017
Showing 1 of 2 known citations — external sources report more than can currently be individually listed.
Related research
- Compliance Test of Percentage Depth Dose (PDD) Using LINAC Machine Brand Electa Precise against American Association of Physicists in Medicine (AAPM) PDD with Electron Beam Energy Variation at Radiotherapy Installation RSUP Prof. Ngoerah in Denpasar — shares topic coverage
- Effect of Dietary Energy and Protein Level and Enzyme Supplementation on Performance and Egg Quality Traits of Laying Hens — shares topic coverage
- Assessment of Biochemical Effect of “Power Horse” Energy Drink on Hepatic, Renal and Histological Functions in Sprague Dawley Rats — shares topic coverage
- Energy Evaluation of Various Compositions of Biomass Waste Briquettes — shares topic coverage
- Effects of Fluidization Velocity and Equivalence Ratio on the Energy and Exergy of the Syngas Produced from Wheat Straw in A Dual-distributor Type Fluidized Bed Gasifier — shares topic coverage
Article metrics
Real usage data collected on this platform.
71
Page views
0
PDF downloads
38
Outbound clicks
2
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.