Skip to content
Research Article Open access CC BY 4.0

RP HPLC Method Development for Simultaneous Estimation of Etoricoxib and Thiocolchicoside

Anchal Sharma, Amit Chaudhary, Bhupendra Singh

Journal of Pharmaceutical Research International · pp. 39–44 · Published 28 Jan 2022

10.9734/jpri/2022/v34i6A35430

Abstract

A simple, specific and accurate reverse phase high performance liquid chromatography (RP-HPLC) method was developed and validated for simultaneous estimation of Etoricoxib and Thiocolchicoside in bulk and solid dosage form. Separation was achieved by Zorbax C-18 analytical column having dimension (250mm * 4.6 mm i.d 5.0 µm) using methanol and water (60:40) as mobile phase and flow rate was 0.7ml/min. The detection was carried out at 283 nm wavelength using UV detector. The total chromatographic sample time per analysis was about 14.0 minutes with thiocolchicoside eluted at retention time 3.523 min and etoricoxib eluted at retention time 9.627 min. The method was validated for accuracy, precision, specificity, rapid, reliable and reproducible. LOD and LOQ value for etoricoxib and thiocolchicoside were found to be 0.332, 0.996 ppm and 0976, 0.928 ppm respectively. Regression Equation for Etoricoxib was y = 0.006x + 0.149 and regression equation for thiocolchicoside was Y = 0.030x + 0.086. As the run time was increased the retention time was decreased, so the method is simple and economical and can be adopted by regular quality control in industries and also in research laboratories.

Etoricoxib thiocolchicoside RP-HPLC validation

Cited by 3

Chemo Metric Assisted Method Development for the Estimation of Paracetamol, Etoricoxib and Thiocolchicoside in Combined Formulation

Shital D. Uparwad, Sonali M. Khapne, Shweta R. Kokare · Asian Journal of Pharmaceutical Analysis · 2024

Showing 2 of 3 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

4

Page views

0

PDF downloads

0

Outbound clicks

3

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.