Skip to content
Research Article Open access CC BY 4.0

RP-HPLC Method Development and Validation of Tapentadol Hydrochloride in Bulk and Pharmaceutical Formulations

G. Sangeetha, M. Swamivel Manickam, P. Sanil Kumar

Journal of Pharmaceutical Research International · pp. 7–16 · Published 15 Mar 2021

10.9734/jpri/2021/v33i1131239

Abstract

Objective: Tapentadol Hydrochloride was approved (November 2008) by the United States Food and Drug Administration for the relief of moderate to severe pain. It is an opioid analgesic, acts by dual mechanism as opioid receptor agonist and norepinephrine reuptake inhibitor. The present research work was aimed to develop an accurate, precise, and rapid RP-HPLC method and subsequently validates the method according to the International Conference on Harmonization (ICH) guidelines for the determination of Tapentadol Hydrochloride. Methods: Tapentadol Hydrochloride was analyzed by using High-Performance Liquid Chromatography. Better separation of the drug was achieved by using a Symmetry C18 column (150x4.6mm, 3.5μm) with the mobile phase consisted of a mixture of Orthophosphoric acid (0.1% of Orthophosphoric acid in HPLC water) and acetonitrile in the ratio of 30:70 v/v at a flow rate of 1 ml/min, and the detection was at the wavelength of 219nm using a PDA detector. Results: The retention time of Tapentadol Hydrochloride was found to be 3.747 ± 0.127 min. The method was found to be linear in the range of 10-200 ug/ml with a correlation coefficient (r2) of 0.9991. The LOD and LOQ of the method were calculated to be 0.1 and 1μg/ml respectively. The method precision and system precision was estimated and the results were calculated as % RSD values, which were found to be within the limits. Recovery of Tapentadol Hydrochloride was found to be 100.1%, which confirms the efficiency of the method. Conclusion: The developed RP-HPLC method was validated using standard ICH guidelines. The developed method can be used for the analysis of both tapentadol hydrochloride bulk and formulations.

RP-HPLC tapentadol hydrochloride validation method development pain management.

Cited by 1

Development and Validation of Ultraviolet and Reverse Phase-high Performance Liquid Chromatographic Method for Estimation of Cilnidipine

B. Samantaray, J. Panda, Satyapriya Mahapatra · Journal of Pharmaceutical Research International · 2021

Article metrics

Real usage data collected on this platform.

6

Page views

0

PDF downloads

0

Outbound clicks

1

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.