Skip to content
Research Article Open access CC BY 4.0

Pulmonary Function Impairment in Female Workers Exposed to Environments with Varied Ambient Air Pollution in the Central Business Area of Lusaka-Zambia

Lumba Siachingili, Fastone M. Goma

Journal of Advances in Medicine and Medical Research · pp. 1–13 · Published 17 Oct 2015

10.9734/BJMMR/2016/20719

Abstract

Aims: To determine the lung function of cleaners exposed to particulate matter of aerodynamic diameter less than 2.5 micrometer (PM2.5) in the streets and offices in Lusaka, Zambia. Study Design: This was a cross sectional study between two groups. Place and Duration of Study: Lusaka city, central business area, between June and August 2014. Methodology: The study included women between 18-50 years of age who had been working as street or office cleaners for 6 months or more. Males and individuals in both groups who used to smoke or were currently smokers, as well as those with a history of respiratory related illnesses or had cardiopulmonary conditions were excluded from the study. The cleaners were interviewed to get information on socio-demographic characteristics and other information using a structured interview schedule. The participants’ lung volumes, forced expiratory volume in one second (FEV1), forced vital capacity (FVC) and their ratio (FEV1/FVC) were measured using a MRI spirobank G spirometer. On the day of the interview, PM2.5 in their work environment was sampled using a personal aerosol monitor (SIDEPAK AM510).   Results: Out of the 90 participants, 45 were street sweepers and 45 were office cleaners. More street sweepers had impaired lung function (FEV1/FVC) 15(75%) than office cleaners 5(25%) p=0.01. FEV1 was also significantly different among street sweepers 12(70.6%) and office cleaners 5(29.4%) p=0.05. PM2.5 measurements revealed significantly high levels of exposure among street sweepers (p=0.001). Participants with impaired lung function (p=.005) and those with reduced FEV1percent predicted were exposed to significantly high concentrations of PM2.5 (p=0.012). Conclusion: Exposure to high PM2.5 concentration is associated with pulmonary function impairment and reduced FEV1 % predicted among cleaners.

Ambient pollution Fine Particulate matter (PM2.5) Forced Expiratory Volume in 1 second (FEV1) Forced Vital Capacity (FVC) lung function status

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

48

Page views

0

PDF downloads

4

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.