Skip to content
Research Article Open access CC BY 4.0

Predictive Modeling for Parametric Analysis of an Air Conditioning System in a 400-seat Auditorium in Warri, Sub-tropical Nigeria

E. D. Edafiadhe, C. C. NwobiOkoye, K. E. Madu, J. L. Chukwuneke

Journal of Engineering Research and Reports · pp. 59–67 · Published 10 Sep 2022

10.9734/jerr/2022/v23i517611

Abstract

Considering the fact that Warri is located in the sub-tropical region of Nigeria which is characterized by excessively high temperature and high humidity, it is necessary to develop an air-conditioning system which can reduce the hot and ambient temperature within a confined space for human comfort. This research presents the design of an air-conditioning system for comfort of occupants in a 400-Seater auditorium. The three independent variables considered for this design are; the number of occupants, air exchange rate and the outdoor temperature. The auditorium was properly measured and the heat generated by the bulbs, appliances and occupants were adequately considered to get the required cooling load. Regression analysis was used to predict and determine the cooling load. Optimization analysis was also done to determine the optimal condition for maximum cooling load. The plant capacity that will provide thermal comfort for the 400 occupants was calculated to be 25 ton of refrigeration (TR).

Air-conditioning system parametric analysis predictive model optimization temperature heat

References (8)

  1. 1 A Textbook of Thermal Engineering
  2. 2 Performance Evaluation of a Thermoelectric Refrigerator
  3. 3 Comparison of two methods of improving dehumidification in air conditioning systems: Hybrid system (refrigeration cycle –rotary desiccant) and heat exchanger cycle [DOI]
  4. 4 Experimental comparison between R409A and R437A performance in a heat pump unit [DOI]
  5. 5 A Method to Evaluate Energy Performance of Buildings Cooled by Room Air Conditioners [DOI]
  6. 6 Study on the design schemes of the air-conditioning system in a gymnasium [DOI]
  7. 7 To Optimize the Effect of Various Parameters on the Performance of Vapor Compression Refrigeration Cycle [DOI]
  8. 8 Hydrometeorological Study of Saturated Vapour Pressure (SVP) of Warri, Nigeria [DOI]

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

30

Page views

0

PDF downloads

4

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.