Determination of the Effect of Green Roofs on Indoor Temperature by the Use of Simulation in a Tropical Landscape
D. Nyame-Tawiah, L. Attuah, C. Koranteng
Journal of Scientific Research and Reports · pp. 12–28 · Published 13 May 2020
10.9734/jsrr/2020/v26i430244Abstract
Aims: To use a simulation base exploration to carry out 6 scenarios of green roof construction methods to determine the most efficient in improving indoor thermal comfort. Study Design: Simulation Design was used as the study design. Place and Duration of Study: The study was conducted at the Department of Horticulture – Kwame Nkrumah University of Science and Technology located at Kumasi-Ghana between 2016 and 2019. Methodology: A simulation experimental setup was done to run for 1 year to cover the two seasons in Ghana. Version 5.0.2 Design Builder and Energy Plus 5.8 was used to work on 6 scenarios using leaf area indexes (LAI) of 2 and 5 as well as soil depth (thickness) of (70-150 mm), 200 mm, 300 mm and 500 mm. Also a real life experiment was done at the Department of Horticulture by constructing 9 test cells and using treatments such as Portulaca grandiflora and Setcreasea purpurea to validate the results for the simulation. The time setup for the simulation was from 12.00 am to 11.59 pm. Results: A leaf area indexes (LAI) of 5 and soil depth of 70 mm-150 mm recorded the lowest simulated temperature ranging from 26.26°C to 29.30°C for scenario one. For scenario two, a leaf area indexes (LAI) of 5 and a soil depth of 200mm recorded the lowest significantly (P≤0.05) indoor temperature in August (26.20°C) and the highest (29.26°C) in March. In February, June and August, significant differences (P≤0.05) were achieved by leaf area indexes (LAI) 5 and soil thickness 500 mm for scenario three. January, March to July indicated significant differences (P≤0.05) between the treatments leaf area indexes (LAI) 2 and soil thickness 300 mm and leaf area indexes (LAI) 5 and soil depth of 300 mm recorded 26.32°C to 29.33°C for August and March respectively for scenario four. A soil depth of 500 mm and leaf area indexes (LAI) of 2 gave significantly (P≤0.05) low temperatures indoors all year (26.27 to 29.32°C) for scenario five and in August leaf area indexes (LAI) 5 and soil thickness of 500 mm recorded the least temperature all year for scenario six. Conclusion: From the exploration, a soil depth of 70 mm – 150 mm and a LAI of 5, LAI of 5 and soil depth of 200 mm and LAI of 2 and soil depth of 500 mm achieved the lowest temperature and performed better in terms of temperature reduction which will lead to thermal comfort of occupants.
Cited by 2
Chima Cyril Hampo, Leah H. Schinasi, Simi Hoque · Building and Environment · 2026
Li Shun, Siti Norzaini Zainal Abidin, Myzatul Aishah Kamarazaly · Sustainable Construction and Heritage Conservation in the Digital Age · 2025
Related research
- Probabilistic and Economical Design of Roof Top Rainwater Harvesting Tank by Simulation Technique — shares topic coverage
- Soil Water and Nitrogen Balance Study of Maize Using CERES Maize Model in DSSAT — shares topic coverage
- Flood Vulnerability Assessment of Settlements in the Niger-benue Trough, Central Nigeria — shares topic coverage
- Spatial Relationship Perception is Not Affected by Short-term Cortical Reorganization — shares topic coverage
- Subbasins Flood Risk Simulations Using 3D and Swat in the River Catchment of Terengganu — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
2
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.