Skip to content
Research Article Open access CC BY 4.0

Modelling, Design and Performance Analysis of LCL Filter for Grid Connected Three Phase Power Converters

A. U. Essien, F. U. Ilo

Journal of Energy Research and Reviews · pp. 36–51 · Published 8 Aug 2022

10.9734/jenrr/2022/v12i130291

Abstract

The use of Power Converters to integrate renewable sources of power with the ac grid has been on the increase in the last two decades. An LCL filter is often used to interconnect the Power Converters to the utility grid in order to filter the high order harmonics produced by the Converter. To achieve the high filtering performance that meet the stringent grid code requirement and also balance cost and effectiveness, an optimal design of the LCL filter is required. This paper presents the modelling and a comprehensive design methodology of an LCL filter for grid – interconnected converters using analytical approach. The simulation results show that with this design method, 99.51% of the current harmonics present at the converter output is mitigated.

LCL filter power converter Total Harmonic Distortion (THD) passive damping

Cited by 5

Grid-connected battery energy storage system using interleaved bidirectional buck/boost converter and 3-level SVPWM inverter

O. Elamri, Jacob Wekalao · International Journal of Power Electronics and Drive Systems (IJPEDS) · 2026

A Systematic Design for Conflicting Constraints in Multi-Mode AC-AC Converters

Tingyi Lin, Wei-Min Wu, Houqing Wang · 2025 4th Asia Power and Electrical Technology Conference (APET) · 2025

Analysis in THD Mitigation Strategies for V2G-G2V Systems: Adaptive, Active, Hybrid, and Passive Filter Performance Under Dynamic and Non-Linear Load Conditions

A. Singh, P. Balakrishnan · 2025 Innovations in Power and Advanced Computing Technologies (i-PACT) · 2025

Design, Modeling and Analysis of LCL Filter for Three Phase Inverter

Bhagyashree S. Choudhari, Nalini Karchi · 2024 IEEE International Conference on Smart Power Control and Renewable Energy (ICSPCRE) · 2024

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

5

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.