Skip to content
Research Article Open access CC BY 4.0

Mid-term Safety and Efficacy of Transcatheter Closure of Ostium Secundum Atrial Septal Defect under Transthoracic Echocardiographic Guidance in Children Weighing Less than 15 Kg

Harmeet Singh Arora, Prashant Bharadwaj, Davinder Singh Chadha, Susheel Malani, Arijit Kumar Ghosh, Kamal Pathak, Deepak Shukla, Sachin Shouche, Satish Kumar Mishra, Jaswinder Singh, Brijindera S. Sethi

Cardiology and Angiology: An International Journal · pp. 1–11 · Published 17 Jun 2019

10.9734/ca/2019/v8i330105

Abstract

Background: Transcatheter device closure of ostium secundum atrial septal defect is a safe & effective intervention in older children, & is usually done under transesophageal echocardiography guidance. However, the procedure under transthoracic echocardiography guidance, especially in smaller children, is done only at few centers, the data of which is scarce. Methods: A prospective study was undertaken to assess the mid-term efficacy and outcome of transcatheter device closure of ostium secundum atrial septal defect  under transthoracic echocardiographic guidance, in children <15 Kg. Results: Eighty three children with ostium secundum atrial septal defect  were included in the study. Median age of the study population was 3.5 years (1.9-5.6 years), and median weight of 11.6 Kg (7.6 - 14.9 Kg). The primary and secondary procedural success rates were 94% and 96.4% respectively. Post procedure patients were followed up for 12-30 months. Device related major complications were encountered in 4 (4.8%) cases. The total occlusion rates of the defect at 24 hours, 1 month and 3 months post procedure were 94%, 98.8% and 100% respectively. Conclusion: The transcatheter device closure of ostium secundum atrial septal defect  under transthoracic echocardiography guidance, in children <15 Kg, has a high short and mid-term safety and efficacy.

Ostium secundum atrial septal defect transthoracic echocardiography transesophageal echocardiography right heart enlargement

References (27)

  1. 1 The incidence of congenital heart disease [DOI]
  2. 2 Early and late complications associated with transcatheter occlusion of secundum atrial septal defect [DOI]
  3. 3 Birth Prevalence of Congenital Heart Disease Worldwide: A Systematic Review and Meta-Analysis [DOI]
  4. 4 Nonoperative closure of atrial septal defects.
  5. 5 Natural history of growth of secundum atrial septal defects and implications for transcatheter closure [DOI]
  6. 6 Embolization and retrieval of the Amplatzer septal occluder [DOI]
  7. 7 Closure of atrial septal defects in children: surgery versus Amplatzer device implantation.
  8. 8 Prospective Randomized Trial of Transthoracic Echocardiography Versus Transesophageal Echocardiography for Assessment and Guidance of Transcatheter Closure of Atrial Septal Defects in Children Using the Amplatzer Septal Occluder [DOI]
  9. 9 Trans-catheter closure of atrial septal defect: Balloon sizing or no balloon sizing - single centre experience [DOI]
  10. 10 Transthoracic echocardiographic guidance during transcatheter closure of atrial septal defects in children and adults [DOI]
  11. 11 Early and late complications associated with transcatheter occlusion of secundum atrial septal defect [DOI]
  12. 12 A comparison between the early and mid-term results of surgical as opposed to percutaneous closure of defects in the oval fossa in children aged less than 6 years [DOI]
  13. 13 Early Complications After Percutaneous Closure of Atrial Septal Defect in Infants with Procedural Weight Less than 15 kg [DOI]
  14. 14 Transcatheter Versus Surgical Closure of Atrial Septum Defect: A Debate from a Developing Country [DOI]
  15. 15 Techniques and outcomes of transcatheter closure of complex atrial septal defects – Single center experience [DOI]
  16. 16 Late bacterial endocarditis of an Amplatzer atrial septal device [DOI]
  17. 17 Transcatheter closure of atrial septal defect in children up to 10 kg of body weight with Amplatzer device [DOI]
  18. 18 Use of a straight, side‐hole delivery sheath for improved delivery of amplatzer ASD occluder [DOI]
  19. 19 Transcatheter closure of atrial septal defect in young children: results and follow-up [DOI]
  20. 20 Late endocarditis of amplatzer atrial septal occluder device in a child [DOI]
  21. 21 Multiple transcatheter interventions in the same session in congenital cardiopathies [DOI]
  22. 22 Device closure of secundum atrial septal defects: To balloon size or not to balloon size [DOI]
  23. 23 Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects [DOI]
  24. 24 TRANSCATHETER VERSUS SURGICAL CLOSURE OF ATRIAL SEPTAL DEFECTS IN CHILDREN: A VALUE COMPARISON [DOI]
  25. 25 Emergency surgery for embolisation of Amplatzer device into the left atrium.
  26. 26 Transcatheter Device Closure of Multiple Atrial Septal Defects in Children Under Body Weight 15kg [DOI]
  27. 27 [Analysis and follow-up study on 8 children with combined congenital heart disease treated with simultaneous trans-catheter therapy].

Cited by 2

Atrial Septal Defect Device Closure. Is Balloon Sizing Necessary?

Ali Eshraghi, Ehsan Aghaei-Moghadam, Aliakbar Zeinaloo · Iranian Journal of Pediatrics · 2021

Showing 1 of 2 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

66

Page views

0

PDF downloads

40

Outbound clicks

2

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.