Skip to content
Research Article Open access CC BY 4.0

Impact of Superstructure Type on Interleukin-1β and Interleukin-6 Levels in Peri Implant Crevicular Fluid: Screw Retained Zirconia Crowns Versus Cement Retained Metal Ceramic Crowns in Healthy and Peri Implantitis Sites

Rawaa Zaher Hassan Zwain, Ahmed Hatif Jawad Ameen, Worood Zaher Hassan Zwain

Journal of Complementary and Alternative Medical Research · pp. 12–21 · Published 28 Apr 2026

10.9734/jocamr/2026/v27i3743

Abstract

Background: The effect of configuration of implant superstructure, namely screw-retained zirconia crowns versus cement retained metal-ceramic crowns on local inflammatory biomarker profiles is not yet fully characterized although emerging evidence demonstrates the effects of superstructure material or retention mechanism on peri-implant health outcomes. Objectives: The aim of this study was to investigate whether the concentrations of IL-1β and IL-6 in PICF were different between screw-retained zirconia crowns and cement-retained metal-ceramic crowns, as well as correlate these inflammatory biomarkers with peri-implant conditions. Methods: A comparative study in cross-sectional design was performed from May 2025 to January 2026 on 66 adult patients with single-tooth implant-supported restorations. Patients received an SLA implant and were randomly assigned into either Group 1 (n=24) with screw-retained monolithic zirconia crowns or Group 2 (n=42) cement-retained metal-ceramic crowns. Peri-implant crevicular fluid samples were obtained from the mesiobuccal aspect of each implant and quantified for IL-1β and IL-6 using enzyme-linked immunosorbent assay (ELISA). Recording of clinical parameters including probing depth and bleeding on probing. Patients were categorized in accordance with peri-implant health status as healthy implants or peri-implantitis sites. Results: The cohort had 56% healthy implants and 44% peri-implantitis systems. Screw-retained zirconia crowns (34.8 ± 7.6 pg/mL) exhibited significantly lower levels of IL-1β compared to cement-retained metal-ceramic crowns (45.7 ± 9.2 pg/mL); t-value = 4.52, p <0.004. Likewise, levels of IL-6 in the cement-retained metal-ceramic group (30.8 ± 7.5 pg/mL) were significantly higher than levels in the screw-retained zirconia group (19.6 ± 5.4 pg/mL), with a t-value of 5.18 and p<0.002 found to be statistically significant as well. In general, IL-1β (48.6 ± 10.1 pg/mL vs. 28.9 ± 6.5 pg/mL, p<0.005) and IL-6 (32.4 ± 8.3 pg/mL vs. 16.7 ± 4.8: Healthy implants p<0·003) levels were significantly higher for peri-implantitis sites in comparison to healthy implants. Conclusion: Screw-retained zirconia crowns have significantly lower IL-1β and IL-6 levels in the peri-implant crevicular fluid than cement-retained metal-ceramic crowns, indicating that superstructure configuration is an important modifiable determinant of peri-implant inflammatory burden.

IL-1β IL-6 crevicular fluid zirconia crowns metal-ceramic crowns

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

18

Page views

0

PDF downloads

3

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.