Impact of Cladding Material and Air Cavity on Ventilated Facades in Warm Semi-Arid Climates
M. F. Ramírez Trejo, J. B. Hernandez Zaragoza, T. López Lara, J. M. Horta Rangel
Current Journal of Applied Science and Technology · pp. 77–88 · Published 20 Jan 2026
10.9734/cjast/2026/v45i14654Abstract
This study examines the high air conditioning demand characteristic of buildings located in warm semi-arid climates, where intense solar radiation and low humidity significantly increase thermal loads on the building envelope. In this context, ventilated facades have emerged as a promising passive strategy capable of reducing heat gain by combining external cladding with a ventilated air cavity. Despite the proven potential of these systems, the literature shows methodological fragmentation and limited evidence specifically focused on warm semi-arid regions. The main objective of this research is to perform a comparative thermal assessment of six ventilated facade configurations generated from the combination of three cladding materials (Dekton, porcelain ceramic, and fiber-cement cladding) and two cavity depths (6 cm and 10 cm). The goal is to identify the relative influence of material properties and cavity geometry under extreme climatic conditions and to establish preliminary design criteria applicable to architectural practice. The methodological approach integrates three components: (1) a selective review of the scientific literature to identify dominant parameters affecting ventilated facade performance; (2) the construction of an analytical matrix to systematize and prioritize these variables; and (3) a simplified thermal modeling procedure based on a one-dimensional series-resistance formulation applied to a southwest-oriented classroom of the Biotechnology Building at the Universidad Autónoma de Querétaro. Representative boundary conditions were adopted (Text = 40 °C, Tint = 26 °C) along with standard convection coefficients for external, internal, and cavity interfaces. Results show that the steady-state heat flux transmitted to the interior remains within a narrow range (≈ 8.06–8.23 W/m²), indicating that cavity ventilation exerts a more dominant effect than cladding conductivity under the adopted assumptions. These findings provide a quantitative foundation for early-stage design decisions in warm semi-arid climates and underline the relevance of cavity depth and insulation in optimizing passive cooling performance.
Cited by 0
No indexed citations yet.
Related research
- Achieve Sustainable Development in 5G Mobile Technology — shares topic coverage
- Minimal Dimensions of a Small House by Means of Optimization Procedure — shares topic coverage
- Study High Performance Thermal Properties of Natural Pumice-Based Bricks — shares topic coverage
- Hydrogen Strategic Complement of Oil, Coal, Gas and Renewable Energy — shares topic coverage
- Performance Analysis of ACO Based Routing Protocols- EMCBR, AntChain, IACR, ACO-EAMRA for Wireless Sensor Networks (WSNs) — shares topic coverage
Article metrics
Real usage data collected on this platform.
54
Page views
0
PDF downloads
6
Outbound clicks
0
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.