Skip to content
Research Article Open access CC BY 4.0

Acute Effects of Ultrasonic Shears and Monopolar Electrosurgery on Sciatic Nerve Electrophysiology

Chaoyang Chen, John M. Cavanaugh, Srinivasu Kallakuri, Katsumasa Tanimoto, Duan Broughton, Jeffrey W. Clymer, Tamara V. Widenhouse, Joseph F. Amaral

Journal of Advances in Medicine and Medical Research · pp. 1–8 · Published 5 Apr 2016

10.9734/BJMMR/2016/25233

Abstract

Background: When using energized surgical devices in the vicinity of nerves, care must be taken to reduce the risk of thermal or electrical injury. For example, during thyroidectomy, it is critical to avoid damage to the recurrent laryngeal nerve while dissecting and coagulating nearby tissue. Methods: We compared use of Harmonic ACE+ and Focus ultrasonic shears and monopolar electrosurgery to scissors as a control applied to make incisions in muscle 2 mm from the sciatic nerve in rats. Via electrophysiological monitoring, the compound action potential and conduction velocity were determined over a three hour post-application period. Neuromuscular response was observed by von Frey hair stimulation. Leukocyte infiltration was measured via H&E staining, and impaired axonal transport via β-APP immunohistology. Results: None of the energized devices had a significantly different compound action potential than scissors, although electrosurgery exhibited prolonged depolarization and repolarization times. Electrosurgery had significantly slower conduction velocity and increased von Frey stimulation force compared to scissors, whereas both ultrasonic devices were not different from the control. No difference was observed between devices for leukocyte infiltration, but electrosurgery had significantly greater β-APP levels than scissors, while again ultrasonic devices were not different. Conclusion: Electrosurgery caused significantly more neurophysiological damage than scissors. In contrast, the ultrasonic shears were not statistically different than scissors in terms of nerve injury. Harmonic ACE+ and Focus can be used to cut and coagulate tissue near nerves with a low risk of electrophysiological injury.

Ultrasonic harmonic electrophysiology surgery nerve injury focus ACE .

Cited by 2

The association between health literacy and self-medication behaviors among women referred to comprehensive health care centers in Sirjan, Iran, in 2017

Somayeh Mousaeipour, Department of Medical Surgical Nursing, School of Nursing and Midwifery; Student Research Center, Rafsanjan University of Medical Sciences, Rafsanjan, Iran., Ali Ansari Jaberi · Journal of Occupational Health and Epidemiology · 2018

Showing 1 of 2 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

2

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.