Comparison of Cardiac Function Evaluation by 128-Slice Single Source Retrospectively Gated Cardiac CT and 2D/M- mode Echocardiography
Pankaj Goyal, Mansi Jain, Rohit Khisti, Kapisoor Singh
Journal of Advances in Medicine and Medical Research · pp. 1–6 · Published 14 Mar 2016
10.9734/BJMMR/2016/24227Abstract
Aims: To study the correlation of Cardiac function/ejection fraction derived from 128 slice MDCT (multi detector computed tomography) results with those of functional data from 2D/M-mode echocardiography. Study Design: Retrospective, comparative study with empirical data. Place and Duration of Study: Department of Radiology at K. Govindaswamy Naidu Medical Trust hospital, Coimbatore, between May 2013 and October 2013. Methodology: For this study, 44 patients (M: F = 35: 9; mean age = 49 years) were randomly chosen who had come between May 2013 and October 2013. All the patients were referred to our department from cardiology as well as non-cardiology OPD’s for coronary CT angiography. Ejection fraction data was obtained using two methods; M-mode echocardiography and 128-slice MDCT using retrospective ECG gated coronary angiographic study. Results: The mean of LVEF (left ventricle ejection fraction) by echo is 64.73 with standard deviation of +/- 5.48 and the mean of LVEF by cardiac CT is 65.18 with standard deviation of +/- 8.70 with P- value of 0.770 (P value ranges from 0-1) which shows good correlation. The evaluation of LVEF by linear regression analysis show good correlation between LVEF by echo and MDCT. (r= 0.486). [r value ranges between -1 and +1]. Conclusion: This study shows the cardiac function evaluation using 128 slice MDCT is as good as the 2D- echocardiography thus the results are interchangeable between the modalities.
Cited by 0
No indexed citations yet.
Related research
- Atrial Function and Glutathione in Children with Iron Deficiency Anemia- Tanta-Egypt-2012 — shares topic coverage
- Evaluation of Right Ventricular Diastolic Function in Patients with Chronic Obstructive Pulmonary Disease Using Pulsed Doppler Tissue Imaging — shares topic coverage
- An Unusual Cause of an Uncommon Condition: Pulmonary Vein Stenosis — shares topic coverage
- Pattern of Congenital Heart Disease among Libyan Children: A Single Centre Study — shares topic coverage
- Double Inlet Left Ventricle (DILV) with Mal-posed Great Vessels: A Challenge in a Developing World — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.