Evaluation and Comparison of the Transverse Strength of Two Heat Cure Denture Base Resins Repaired with Auto Polymerizing Resin by Wetting with Methyl Methacrylate (MMA) at Different Time Intervals - An In vitro Study
S. K. Shakeel, Rama Krishna Alla, Shammas Mohammed, Tajammul Ahmed
Journal of Advances in Medicine and Medical Research · pp. 263–271 · Published 18 Feb 2015
10.9734/BJMMR/2015/15774Abstract
Aims: Fracture of dentures is a common clinical finding in daily prosthodontic practice, resulting in great inconvenience to both the patient and the dentist. A satisfactory repair should be cost-effective, simple to perform, and quick. This study evaluated and compared the transverse strength of two heat cure denture base resins repaired with auto polymerizing resin by wetting with methyl methacrylate (MMA) at different time intervals. Materials and Methods: Stellon and Trevalon denture base materials were used in the study. A total of 200 heat cure acrylic resin specimens (100 specimens each of Stellon and Trevalon acrylic material) with the dimensions of (65 mm x 10 mm x 3 mm) were prepared. The specimens were divided with 10 specimens for each of the test groups (n =10). The test groups were designated as Group A through J. Repair gap of 2 mm was prepared in the centre of the specimen. The repair surface of the specimens were wetted with MMA at different time intervals (1, 2, 3, 4, 5, 10, 15 and 30 minutes) and repaired by using auto polymerizing resin. The transverse strength of the repaired specimens was tested by a 3 point bending test. All data was statistically analyzed with one-way ANOVA, differences within the groups were analyzed by independent sample t -test. Results: The results showed that the significant difference between the specimens wetted with MMA at different time intervals. A gradual increase was shown in the mean transverse strength of repaired specimens wetted from 1 minute to 5 minutes in Stellon and from 1 minute to 10 minutes in Trevalon. Conclusion: Wetting the repair surfaces with MMA for a period of more than 5 minutes and 10 minutes in case of Stellon and Trevalon respectively increases the incidence of adhesive failure in the repaired specimens.
Cited by 1
Rama Krishna Alla, K. N. Raghavendra Swamy, R. Vyas · 2017
Related research
- Influence of Silver Nanoparticles Incorporation on Flexural Strength of Heat-cure Acrylic Denture Base Resin Materials — shares topic coverage
- Evaluation of the Transverse Strength of the Heat Cure PMMA Resin Reinforced with Various Concentrations of Two Different Nanoparticles: An In vitro Study — shares topic coverage
Article metrics
Real usage data collected on this platform.
18
Page views
0
PDF downloads
2
Outbound clicks
1
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.