Estimated Power Output from a Simplified Pico Hydropower System
Alex Okibe Edeoja, Joshua Sunday Ibrahim, Lawrence Ochonu
Journal of Energy Research and Reviews · pp. 1–16 · Published 30 May 2018
10.9734/jenrr/2018/v1i19775Abstract
Based on the results of no-load tests carried out on a simplified Pico hydropower system currently undergoing development, on-load tests were carried out. A turbine of runner diameter 0.40 m, penstock diameters in the range and nozzle area ratios in the range were used for the on-load tests. A 2.5 kW alternator was linked to the turbine using a v-belt drive on pulleys of ratio 6:1. The effective vertical height from the outlet of the reservoir to the plane of the turbine shaft was 6.95 m. A 0.74 kW electric pump was used to recycle the water to the overhead reservoir. The rotational speeds of the turbine and alternator shafts, the volume of water displaced and voltage were measured for each penstock diameter and nozzle area ratio. The measured data were used to compute the system volumetric flow rate and to estimate the power output based on the alternator manufacturer’s specifications. The turbine efficiency was also computed. The system developed a maximum voltage of 224 V with and a minimum voltage of 111 V with and . The corresponding estimated power outputs were 2.125 kW and 1.545 kW respectively. The mean maximum and minimum efficiencies based on the estimated power output were 0.85 and 0.618 respectively. The overall results indicate very good potential for the system as a clean, decentralized small power generation unit that gives control to the user.
Cited by 2
Alex Okibe Edeoja, Samuel Lawal, Gertrude Enekole Aboje, Kenneth Ede Ode, Jacob S. Ibrahim · Journal of Engineering Research and Reports · 2022
A. Edeoja, Gertrude Enekole Aboje, Samuel Lawal · Journal of Energy Research and Reviews · 2022
Related research
- Turbine Dimensionless Coefficients and the Net Head/Flow Rate Characteristic for a Simplified Pico Hydro Power System — shares topic coverage
- Influence of Number of Flat Locally-Fabricated Turbine Blades on the Performance of a Simplified Pico Hydropower System — shares topic coverage
- Effect of the Number of Splined Blades of a Locally-Fabricated Turbine on the Performance of a Simplified Pico Hydropower System — shares topic coverage
- Performance Evaluation of a Pump as Turbine in a Simplified Pico Hydropower System with Provision for Water Recycling — shares topic coverage
Article metrics
Real usage data collected on this platform.
29
Page views
0
PDF downloads
4
Outbound clicks
2
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.