Skip to content
Research Article Open access CC BY 4.0

Determination of Body Fat Percentage by Body State Devices and Dual Energy X-Ray Absorptiometry

Reham A. Mostafa, Doaa R. Negm, Naser A. ElSawy

Asian Journal of Medicine and Health · pp. 1–12 · Published 26 Dec 2019

10.9734/ajmah/2019/v17i230163

Abstract

Background: Dual energy X-ray absorptiometry (DEXA) is the most accurate technique in determining fat percentage but it is unpotable, expensive, unavailable for general applicability. Objective: This study aimed to find the most accurate and easiest technique as alternative to DEXA for quick determination of body fat%. This study examined the accuracy of three models of Bioelectrical impedance analysis (BIA) technique (Fat Loss Monitor- Body Composition -Body Fat Analyzer) in determining the body fat percentage with using DEXA as a reference standard. Subject and Methods: A cross sectional study was carried out during the period from (28-9-2017) to (5-4-2018) among a random sample of (53) volunteers female student in Umm Al Qura University from Faculty of Applied Medical Science aged between (20-39 years) from different level of education. All subjects were generally healthy, data was collected through a structured questionnaire compose of three section. Demographic data was collected and anthropometric measurements were evaluated as well as body composition (Only body fat%) using DEXA, body composition monitor, fat loss monitor and body fat analyzer. Results: BMI classification of the total 53 subjects was including 8 healthy females, 17 overfat, 25 obese and 3 underweight. The fat% result from DEXA and body fat analyzer was significant difference at (P < 0.05). Fat percent result from DEXA and Body Composition device was non-significant difference at (P>0.05). The fat% result from DEXA and Fat Loss Monitor device was significant at difference (P<0.05). Conclusion: The most accurate of BIA technique was the Body Composition device compering to DEXA.

BIA technique body composition body fat analyzer body fat percentage DEXA fat loss monitor.

References (18)

  1. 1 Bioelectrical impedance analysis—part II: utilization in clinical practice [DOI]
  2. 2 Assessment methods in human body composition [DOI]
  3. 3 Accuracy of direct segmental multi-frequency bioimpedance analysis in the assessment of total body and segmental body composition in middle-aged adult population [DOI]
  4. 4 Bioelectrical Impedance Analysis: A Review of Principles and Applications [DOI]
  5. 5 Comparison of multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of percentage body fat in a large, healthy population [DOI]
  6. 6 In vivo validation of whole body composition estimates from dual-energy X-ray absorptiometry [DOI]
  7. 7 Body Composition Measurement: A Review of Hydrodensitometry, Anthropometry, and Impedance Methods [DOI]
  8. 8 Comparison of Three Bioelectrical Impedance Methods with DXA in Overweight and Obese Men [DOI]
  9. 9 Comparison of skinfold thicknesses and bioelectrical impedance analysis with dual-energy X-ray absorptiometry for the assessment of body fat in patients on long-term haemodialysis therapy [DOI]
  10. 10 Bioimpedance for Severe Obesity: Comparing Research Methods for Total Body Water and Resting Energy Expenditure [DOI]
  11. 11 Prediction of fat-free mass by bioimpedance analysis in migrant Asian Indian men and women: a cross validation study [DOI]
  12. 12 Evaluation of Multifrequency Bioelectrical Impedance Analysis in Assessing Body Composition of Wrestlers [DOI]
  13. 13 Comparison of the validity of anthropometric and bioelectric impedance equations to assess body composition in adolescent girls.
  14. 14 Comparison of Body Fat Results from 4 Bioelectrical Impedance Analysis Devices vs. Air Displacement Plethysmography in American Adolescent Wrestlers [DOI]
  15. 15 Body Protein Index Based on Bioelectrical Impedance Analysis Is a Useful New Marker Assessing Nutritional Status: Applications to Patients with Chronic Renal Failure on Maintenance Dialysis [DOI]
  16. 16 Accuracy of Consumer Grade Bioelectrical Impedance Analysis Devices Compared to Air Displacement Plethysmography [DOI]
  17. 17 Exercise Is Medicine [DOI]
  18. 18 Bone mineral density and body composition in Saudi adult females [DOI]

Cited by 6

The Association Between Obesity and Key Health or Psychosocial Outcomes Among Autistic Adults: A Systematic Review

Daniel Gilmore, Anne Longo, Brittany N. Hand · Journal of Autism and Developmental Disorders · 2021

Showing 4 of 6 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

56

Page views

0

PDF downloads

13

Outbound clicks

6

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.