Skip to content
Research Article Open access CC BY 4.0

Critical Analysis of Corneal Cross-linking (Part-I): Formulas for Efficacy, Safety Dose, Minimum Thickness, Demarcation Line Depth and the Role of Oxygen

Sheng-Fu Cheng, Jui-Teng Lin

Ophthalmology Research: An International Journal · pp. 29–41 · Published 11 Aug 2021

10.9734/or/2021/v14i430200

Abstract

Purpose: To update and derive formulas for the efficacy and kinetics of corneal collagen crosslinking (CXL) including both type-I and oxygen-mediated type-II mechanisms, the role of oxygen, the initiator regeneration, safety dose, minimum corneal thickness and demarcation line depth. Study Design: Modeling the kinetics of CXL in UV light and using riboflavin as the photosensitizer. Place and Duration of Study: Taipei, Taiwan, between June, 2021 and July, 2021. Methodology: Coupled kinetic equations are derived under the quasi-steady state condition for the 2-pathway mechanisms of CXL. For type-I CXL, the riboflavin (RF) triplet state [T] may interact directly with the stroma collagen substrate [A] to form radical (R) and regenerate initiator. For type-II process, [T] interacts with oxygen to form a singlet oxygen [1O2]. Both reactive radical (R) and [1O2], can interact with the substrate [A]) for crosslinking. Based on a safety dose and a threshold dose, formulas for the minimum corneal thickness and demarcation line depth (DLD) are derived. Results: Our updated theory/modeling showed that oxygen plays a limited and transient role in the process, in consistent with that of Kamave. In contrary, Kling et al believed that type-II is the predominant mechanism, which however conflicting with the epi-on CXL results. For both type-I and type-II, a transient state conversion (crosslink) efficacy in an increasing function of light intensity (or dose), whereas, its steady state efficacy is a deceasing function of light intensity. RF depletion in type-I is compensated by the RF regeneration term (RGE) which is a decreasing function of oxygen. For the case of perfect regeneration case (or when oxygen=0), RF is a constant due to the catalytic cycle. Unlike the conventional Dresden rule of 400 um thickness, thin cornea CXL is still safe as far as the dose is under a threshold dose (E*), based on our minimum thickness formula (Z*). Our formula for thin cornea is also clinically shown by Hafez et al for ultra thin (214 nm) CXL. Conclusion: For both type-I and type-II, the transient state conversion (crosslink) efficacy in an increasing function of light intensity (or dose), whereas, its steady state efficacy is a deceasing function of light intensity. CXL for ultra thin corneas are still safe, as far as it is under a threshold dose (E*), based on our minimum thickness (Z*) formula, which has a similar tend as that of demarcation line depth (Z').

Corneal crosslinking efficacy kinetic modeling oxygen riboflavin ultraviolet light safety dose minimum thickness

References (11)

  1. 1 Individualized Corneal Cross-linking With Riboflavin and UV-A in Ultrathin Corneas: The Sub400 Protocol [DOI]
  2. 2 On the in vivo photochemical rate parameters for PDT reactive oxygen species modeling [DOI]
  3. 3 Evaluation of Corneal Stromal Demarcation Line Depth Following Standard and a Modified-Accelerated Collagen Cross-linking Protocol [DOI]
  4. 4 Corneal stromal demarcation line after accelerated crosslinking using continuous and pulsed light [DOI]
  5. 5 Correlation of the Corneal Collagen Cross-Linking Demarcation Line Using Confocal Microscopy and Anterior Segment Optical Coherence Tomography in Keratoconic Patients [DOI]
  6. 6 An Algorithm to Predict the Biomechanical Stiffening Effect in Corneal Cross-linking [DOI]
  7. 7 Comparative Functional Outcomes After Corneal Crosslinking Using Standard, Accelerated, and Accelerated With Higher Total Fluence Protocols [DOI]
  8. 8 Modeling the efficacy profiles of UV-light activated corneal collagen crosslinking [DOI]
  9. 9 Demarcation Line Evaluation of Iontophoresis-Assisted Transepithelial Corneal Collagen Cross-linking for Keratoconus [DOI]
  10. 10 Photochemical Kinetic Modeling for Oxygen-enhanced UV-light-activated Corneal Collagen Crosslinking [DOI]
  11. 11 10.5405/jmbe.1532 [DOI]

Cited by 4

Analysis of Dynamic Efficacy Profile of Corneal Cross-Linking: Role of Oxygen and Rate Constants in Type-I and II Processes

Jui-Teng Lin, Yi-Ze Lee · Ophthalmology Research: An International Journal · 2021

Showing 3 of 4 known citations — external sources report more than can currently be individually listed.

Article metrics

Real usage data collected on this platform.

81

Page views

0

PDF downloads

13

Outbound clicks

4

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.