Skip to content
Research Article Open access CC BY 4.0

Corneal Melting after Crosslinking: A Systematic Literature Review

Rebeca Andrade Ferraz, Vitor Hugo Auzier Lima, Joacy Pedro Franco David, Maria Isabel Muniz Zemero, Débora Silva Nunes, Syenne Pimentel Fayal, Feliphe Palheta Barroso, Tainá Guimarães Barros, José Jesu Sisnando D’Araújo Filho

Journal of Advances in Medicine and Medical Research · pp. 109–121 · Published 2 Dec 2025

10.9734/jammr/2025/v37i126002

Abstract

The crosslinking (CXL) has established itself as a fundamental treatment for stabilizing keratoconus; however, serious complications such as corneal melting represent significant challenges to its safety. Therefore, this systematic review aimed to elucidate the occurrence of post-CXL corneal melting and relate it to relevant technical and clinical parameters. To this end, this research followed the PRISMA guidelines and was conducted between January and March 2025, searching the PubMed, Scopus, Web of Science, SciELO, BVS, and Google Scholar databases. Fifteen studies were selected after rigorous screening based on predefined inclusion and exclusion criteria. The extracted data included CXL protocols, previous pachymetry values, time of melting occurrence, and clinical management. After analyzing this study, it was revealed that corneas with pachymetry below 400 µm presented a significantly increased risk of melting, particularly when subjected to accelerated (FAST) or adapted (sub-400) protocols; furthermore, the Dresden protocol demonstrated greater safety, while technical variants with hypoosmolar riboflavin showed a high potential for complications. Moreover, the time interval for the onset of melting showed a bimodal distribution: most cases occurred in the first few weeks post-procedure, but reports documented late occurrence, with cases appearing between 5 and 12 years after CXL. Therefore, it was identified that additional factors, such as systemic comorbidities (diabetes) and individual inflammatory response, modulated the risk and chronology of the complication. Therefore, it is concluded that post-CXL corneal melting, although rare, has an increased occurrence in thin corneas subjected to modified protocols, requiring prolonged clinical monitoring. Furthermore, careful candidate selection based on preoperative pachymetry and appropriate protocol is fundamental to minimizing this devastating complication, making the development of evidence-based clinical guidelines imperative to optimize the risk-benefit ratio of the procedure.

Keratoconus corneal collagen crosslinking corneal melting corneal pachymetry postoperative complications

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

0

Page views

0

PDF downloads

0

Outbound clicks

0

Citations

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

No views recorded yet.

Traffic sources

Referring site, by host.

No traffic recorded yet.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.