10.9734/jerr/2018/v2i19883Abstract
The ratio of real power flowing into the load to the apparent power in a circuit is referred to as the power factor (PF). It has no unit as its values lie between 0 and 1. Power factor correction (PFC) leads to a reduction in apparent power drawn from the ac source which in turn saves energy and minimizes the transmission losses. This paper reviews various methods used for PFC as well as the various control measures for power factor. The correction methods include distributed PFC, group PFC, centralized PFC and combined PFC. Distributed PFC is applicable to large electrical equipment with constant load and power with long connection times. Combined PFC is the hybrid between a distributed and a centralized correction method. Peak current control technique makes use of constant switching frequency even though, the presence of sub-harmonic oscillations at a duty cycle greater than 50% is a disadvantage. The presence of constant switching frequency and better input current waveforms are some of the applications of average current control. In the discontinuous current pulse width modulation (PWM) control, the internal current loop is completely eliminated so that the switch is at a constant frequency. In nonlinear carrier controllers, the duty ratio is determined by comparing a signal derived from the main switch current with a periodic nonlinear carrier waveform. Therefore, combined PFC and nonlinear carrier controllers are more accurate PFC methods for the power plant because they employ a high power factor boost converter with low total harmonic distortion for installations of large equipment with a constant load. This research paper forms a basis for power system planning as it assists in recommending the appropriate and adequate technique(s) for correcting and controlling the pf of the factory.
References (13)
- 1 Single phase power factor correction: a survey [DOI]
- 2 State-of-the-Art, Single-Phase, Active Power-Factor-Correction Techniques for High-Power Applications—An Overview [DOI]
- 3 Reactive Power Compensation in Single-Phase Operation of Microgrid [DOI]
- 4 Microcontroller based PWM controlled four switch three phase inverter fed induction motor drive [DOI]
- 5 Period-doubling bifurcation in two-stage power factor correction converters using the method of incremental harmonic balance and Floquet theory [DOI]
- 6 A review of electronic inductor technique for power factor correction in three-phase adjustable speed drives [DOI]
- 7 A Novel Power Factor Correction System Based on Sliding Mode Fuzzy Control [DOI]
- 8 FPGA Based V/f Control of Three Phase Induction Motor Drives Integrating Super-Lift Luo Converter [DOI]
- 9 Fundamental Sequence Component Based Hysteresis Current Controlled MSALC [DOI]
- 10 Research of the Single-switch Active Power Factor Correction for the Electric Vehicle Charging System [DOI]
- 11 Design And Simulation Of Ccm Boost Converter For Power Factor Correction Using Variable Duty Cycle Control [DOI]
- 12 Comparative Study of Power Factor Correction and THD Minimization Using Boost Converter and Interleaved Boost Converter Using Pi Controller [DOI]
- 13 Active Power Factor Correction Using Hysteresis Current Control of Boost Converter [DOI]
Cited by 2
Quentin Bellec · 2021
Showing 1 of 2 known citations — external sources report more than can currently be individually listed.
Related research
- Quantitative Design and Evaluation of EMI Filters in a Digitally Controlled Boost PFC Converter — shares topic coverage
- Optimal Placement of Capacitor Bank on Ondo 132/33KV Transmission Substation — shares topic coverage
Article metrics
Real usage data collected on this platform.
82
Page views
0
PDF downloads
17
Outbound clicks
2
Citations
Views over time
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
Traffic sources
Referring site, by host.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.