Contribution of the Provençal Well for the Improvement of the Thermal Comfort in the Building in Turbulent Regime
Kokou N’wuitcha, Ouro-Djobo Essoavana Samah, Yendouban Kolani, Magolmèèna Banna, Belkacem Zeghmati
Asian Journal of Physical and Chemical Sciences · pp. 41–68 · Published 31 Dec 2022
10.9734/ajopacs/2022/v10i4189Abstract
In the current energy context, geothermal systems are highly developed in the building field. Among these interesting systems on the energy plan, one finds in particular the earth-to-air heat exchanger commonly called ‘Canadian or Provençal well’. It consists of tubes buried in which the ambient air is pushed in order to be refreshed in contact with the ground whose temperature is quasi-constant throughout the year. In this work, a study of the performance of an earth-to-air heat exchanger was undertaken by means of numerical modeling of heat exchange by forced convection in a buried tube. The transfer equations in the tube are discretized using the finite volume method in turbulent regime and solved using the Thomas algorithm. For the determination of the ground temperature, the model of the semi-infinite mass subjected to a periodic excitation was adopted. The soil temperature was used as a boundary condition for the buried tube. The results show that the interest of the earth-to-air heat exchanger is major, since it improves throughout the year, the thermal conditions sought. It intervenes in an effective way on the damping of the thermal amplitudes in the building. The variation of the diameter and the length of earth-to-air heat exchanger does not influence notably the distribution of the streamlines and isotherms but affect significantly the values of stream function and temperature inside de tube of the earth-to-air heat exchanger. When diameter of the pipe increases, the outlet temperature increases. The increase of the length of the earth-to-air heat exchanger leads to the isotherms increase as a result of the intensification of heat exchange between the walls and the convective jet. The temperature in the air outlet compartment is lower as the length of the earth-to-air exchanger increases.
Cited by 0
No indexed citations yet.
Related research
- Material Selection and Fluid Flow Analysis of Parallel Flow Heat Exchanger — shares topic coverage
- Heat Transfer and Solidification of Molten Iron in a Pipe — shares topic coverage
- Heat Transfer Aspects on Rotating MHD Two-phase Convective Flow through an Inclined Channel in the Presence of Electric Field — shares topic coverage
- Effects of Suction and Thermal Radiation on Heat Transfer in a Third Grade Fluid over a Vertical Plate — shares topic coverage
- Thermal Behaviour of Bone Cement in Hip Replacement — shares topic coverage
Article metrics
Real usage data collected on this platform.
0
Page views
0
PDF downloads
0
Outbound clicks
0
Citations
Views by country
Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".
No views recorded yet.
Traffic sources
Referring site, by host.
No traffic recorded yet.
Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.