Skip to content
Research Article Open access CC BY 4.0

Comprehensive Assessment of Ferroresonance and its Effects in Selected Distribution Substations in Nasarawa State, Nigeria

Samson Dauda Yusuf, Aminu Alhaji Abdulhamid, Barnabas John Kwaha

Physical Science International Journal · pp. 84–104 · Published 23 Nov 2024

10.9734/psij/2024/v28i6861

Abstract

Ferroresonance in distribution networks generates harmful harmonics, excessive heating, and potential transformer failures, yet limited research focuses on its impact in Nigerian low-voltage systems. This study examines ferroresonance susceptibility in low-voltage distribution transformers, with an emphasis on core saturation, harmonic distortion, and grading capacitance effects under varied operational conditions across substations in Lafia, Akwanga, and Keffi. By analyzing transformer responses from 50V to 500V and harmonic profiles in Delta (1.12Ω) and Star-Grounded (1.53Ω) configurations, the research highlights transformer design's critical role in ferroresonance resilience. Findings reveal that increasing grading capacitance from 90 pF to 1550 pF substantially elevated peak voltages from 0.420kV to 2.400kV (Lafia), 2.450kV (Akwanga), and 2.540kV (Keffi), and currents from 28A, 26A and 27A to 103A, 118A, and 130A, respectively. Voltage THD similarly rose from 6.5%, 6.3% and 6.7% to 35.5%, 38.2%, and 36.0%, respective; with current THD climbing from 7.8% 7.5% and 7.9% to 40.2%, 44.1%, and 42.3% respectively, indicating varying ferroresonance susceptibility across the substations. Delta configurations show lower ferroresonance risk compared to Star-Grounded types, underscoring optimal winding configuration and capacitance management as key resilience factors. Recommendations include targeted harmonic filtering and precise capacitance management to stabilize transformer operation. Future research should consider broader transformer model diversity, adaptive control systems, and machine learning techniques for enhanced ferroresonance risk assessments.

Ferroresonance distribution transformers harmonic distortion grading capacitance core saturation transformer resilience

Cited by 0

No indexed citations yet.

Article metrics

Real usage data collected on this platform.

22

Page views

0

PDF downloads

3

Outbound clicks

0

Citations

Views over time

Views by country

Approximate, from request IP at view time — not citizenship or institution. Countries with fewer than 5 views are grouped as "Other".

Traffic sources

Referring site, by host.

Views and downloads exclude known bots/crawlers. Citations combines this platform's own DOI-resolved index with each external source's own reported total — see Cited by above for individually listed citing works. Last refreshed 0 seconds ago.